Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
1 Spec No
pubmed:dateCreated
1990-3-16
pubmed:abstractText
Interobserver reproducibility in deriving cardiac output by measuring aortic blood flow velocity and diameter with imaging and Doppler ultrasound was investigated in 20 healthy infants born at full term. Aortic diameter was measured in three ways. Mean blood flow velocity was measured at three sites with both continuous wave and pulsed Doppler. Two observers carried out each study independently. Intraobserver reproducibility was investigated in 12 infants using the suprasternal site for measuring blood flow velocity. The most reproducible determination of cardiac output was found when the suprasternal site with continuous wave Doppler was used for measurement of blood flow velocity and M mode trailing edge to leading edge echocardiography was used for diameter. Normal mean (2 SD) cardiac output is 231 (77) ml/kg/min. Technical difficulties in measuring aortic diameter accurately limit direct comparison between infants.
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/2407197-1216365, http://linkedlifedata.com/resource/pubmed/commentcorrection/2407197-150486, http://linkedlifedata.com/resource/pubmed/commentcorrection/2407197-2932675, http://linkedlifedata.com/resource/pubmed/commentcorrection/2407197-3432113, http://linkedlifedata.com/resource/pubmed/commentcorrection/2407197-3880565, http://linkedlifedata.com/resource/pubmed/commentcorrection/2407197-3884219, http://linkedlifedata.com/resource/pubmed/commentcorrection/2407197-4056980, http://linkedlifedata.com/resource/pubmed/commentcorrection/2407197-443037, http://linkedlifedata.com/resource/pubmed/commentcorrection/2407197-593761, http://linkedlifedata.com/resource/pubmed/commentcorrection/2407197-6518060, http://linkedlifedata.com/resource/pubmed/commentcorrection/2407197-6738114, http://linkedlifedata.com/resource/pubmed/commentcorrection/2407197-7086622, http://linkedlifedata.com/resource/pubmed/commentcorrection/2407197-7408149
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
AIM
pubmed:status
MEDLINE
pubmed:month
Jan
pubmed:issn
1468-2044
pubmed:author
pubmed:issnType
Electronic
pubmed:volume
65
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
15-9
pubmed:dateRevised
2009-11-18
pubmed:meshHeading
pubmed:year
1990
pubmed:articleTitle
Reproducibility of measurements of cardiac output in newborn infants by Doppler ultrasound.
pubmed:affiliation
Royal Hospital for Sick Children, Yorkhill, Glasgow.
pubmed:publicationType
Journal Article, Research Support, Non-U.S. Gov't