Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
2
pubmed:dateCreated
1990-3-8
pubmed:abstractText
Among the main causes for the relatively small number of organ donors, the delay in the diagnosis of brain death plays a major role. This prospective study was designed to evaluate whether pulsed Doppler mean and phasic common carotid blood flow (CCBF) combined with arterial and jugular venous blood gases could rapidly and specifically establish a diagnosis of brain death. CCBF was measured by an 8 MHz pulsed Doppler flowmeter, allowing measurement of the vessel diameter via a double transducer probe, which fixed the ultrasonic incidence angle. From an initial series of patients (n = 28) with an established diagnosis [brain death n = 14; severe coma with a Glasgow Coma Scale (GCS) less than 7, n = 14], the results of the logistic regression analysis process yielded the most discriminating parameters for brain death diagnosis: end-diastolic velocity (Ved - 1.4 vs. 12.7 cm/s; t = 7.67, P = 0.001) and blood flow (Qed - 13.6 vs. 121.4 ml/min). These parameters were then tested in a blind fashion on a second series of 28 comatose patients (GCS = 7). They resulted in correct diagnosis (brain death n = 14 or severe coma n = 14) for all patients. Brain death diagnosis was confirmed by clinical signs, EEG, and/or angiography. From the analysis of the overall population (n = 56), a value of Qed of less than 31.4 ml/mn indictes brain death. The authors conclude, that pulsed Doppler measurements of CCBF represent an early, low cost and noninvasive technique, the results of which may prompt legally accepted procedures, which in turn would reduce the delay required before brain death is diagnosed. Moreover, this technique could help in deciding on discontinuation of active therapy in severely injured patients.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
AIM
pubmed:status
MEDLINE
pubmed:month
Feb
pubmed:issn
0003-3022
pubmed:author
pubmed:issnType
Print
pubmed:volume
72
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
222-9
pubmed:dateRevised
2007-11-15
pubmed:meshHeading
pubmed:year
1990
pubmed:articleTitle
Evaluation of pulsed Doppler common carotid blood flow as a noninvasive method for brain death diagnosis: a prospective study.
pubmed:affiliation
Département d'Anesthésie-Réanimation, Hôpital Universitaire Lariboisière, Paris, France.
pubmed:publicationType
Journal Article, Research Support, Non-U.S. Gov't