8
|
pubmed:dateCreated |
1990-12-5
|
pubmed:abstractText |
An improved high performance liquid chromatographic assay (HPLC) is presented for the quantitative determination of prednisone and its main metabolite prednisolone. This HPLC assay, employing a UV-detector and dexamethasone as an internal standard, provides a selective and sensitive determination of glucocorticoids in plasma. The advantage of this method is the possibility of simultaneously measuring exogenic and endogenic glucocorticoids. The lower limit of quantification is 5 ng/ml.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Aug
|
pubmed:issn |
0004-4172
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
40
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
926-31
|
pubmed:dateRevised |
2004-11-17
|
pubmed:meshHeading | |
pubmed:year |
1990
|
pubmed:articleTitle |
Development of a high performance liquid chromatography method for the simultaneous measurement of prednisone and prednisolone.
|
pubmed:affiliation |
Analytical Research Centre of the LAB GmbH, Neu Ulm, Fed. Rep. of Germany.
|
pubmed:publicationType |