Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
5
pubmed:dateCreated
1990-12-24
pubmed:abstractText
We reviewed the transpulmonary gradient, pulmonary arterial systolic pressure, pulmonary vascular resistance (Wood units), and pulmonary vascular resistance index (Wood units X Body surface area), recorded preoperatively in 109 recipients aged 44.6 +/- 13.5 (mean +/- SD) years who underwent orthotopic heart transplantation between March 1984 and March 1988, to identify which measure of pulmonary hypertension most accurately predicts poor outcome after orthotopic heart transplantation. These recipients were followed up as many as 57 (24.7 +/- 14.5) months after their transplant procedure. Preoperative hemodynamic values were as follows: transpulmonary gradient, 10.4 +/- 4.7 mm Hg; pulmonary artery systolic pressure, 53.6 +/- 14.8 mm Hg; pulmonary vascular resistance, 2.7 +/- 1.8 Wood units; pulmonary vascular resistance index, 4.9 +/- 2.7. Nineteen recipients died within 1 year after orthotopic heart transplantation. Causes of death were acute rejection (8), chronic rejection (1), infection (2), nonspecific orthotopic heart transplant failure (4), bowel ischemia (1), pancreatitis (1), lymphoma (1), and liver failure (1). Preoperative pulmonary arterial systolic pressure, pulmonary vascular resistance, and pulmonary vascular resistance index were not predictive of 1-month, 6-month, or 1-year mortality. One-month mortality rates of orthotopic heart transplant recipients with transpulmonary gradient greater than or equal to 12 mm Hg and of those with transpulmonary gradient less than 12 mm Hg were not significantly different (11% vs 3%; p = 0.12). The 6-month mortality rate of orthotopic heart transplant recipients with transpulmonary gradient greater than or equal to 12 mm Hg, however, was five times greater than that of orthotopic heart transplant recipients with transpulmonary gradient less than 12 mm Hg (24% vs 5%; p = 0.003), and 12-month mortality of orthotopic heart transplant recipients with transpulmonary gradient greater than or equal to 12 mm Hg was increased sevenfold when compared with that of orthotopic heart transplant recipients with transpulmonary gradient less than 12 mm Hg (36% vs 5%; p = 0.0005). These results suggest that presently used measures of pulmonary hypertension do not predict mortality in the first month after orthotopic heart transplantation, but that elevated preoperative transpulmonary gradient is associated with a significant increase in mortality at 6 and 12 months after orthotopic heart transplantation. Prospective randomized trials are needed to determined whether extended preload and afterload reduction before and/or after transplant will favorably influence long-term prognosis of orthotopic heart transplant recipients with elevated preoperative transpulmonary gradient.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:issn
0887-2570
pubmed:author
pubmed:issnType
Print
pubmed:volume
9
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
526-37
pubmed:dateRevised
2006-11-15
pubmed:meshHeading
pubmed:articleTitle
Influence of preoperative transpulmonary gradient on late mortality after orthotopic heart transplantation.
pubmed:affiliation
Section of Cardiology, Hines Veterans Administration Medical Center, Ill.
pubmed:publicationType
Journal Article, Comparative Study