pubmed:abstractText
Damage to the peripheral nervous system by neurotoxic agents can result in elevated sensory thresholds. In this study, the results of two studies in a program of validation of vibrotactile threshold test performance are presented. First, the test-retest reliability and time efficiency of two methods for generating vibrotactile thresholds were determined in a sample of subjects known to be at risk for peripheral neuropathy, 22 diabetics. Specifically, a forced-choice method was compared to a method-of-limits procedure. The method of limits was found to be as reliable as the forced-choice procedure and required less time to administer. The second study was undertaken to determine the magnitude of major effect modifiers on vibrotactile thresholds. Vibration thresholds were determined using a method-of-limits procedure in 131 blue-collar workers who were 29-76 y of age. Equations relating vibrotactile threshold estimated by the method-of-limits procedure to age and height are presented for the upper and lower extremities.
pubmed:grant
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
AIM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:issn
0003-9896
pubmed:author
pubmed:issnType
Print
pubmed:volume
45
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
148-54
pubmed:dateRevised
2007-11-14
pubmed:meshHeading
pubmed-meshheading:2167042-Adult, pubmed-meshheading:2167042-Age Factors, pubmed-meshheading:2167042-Aged, pubmed-meshheading:2167042-Asbestos, pubmed-meshheading:2167042-Body Weight, pubmed-meshheading:2167042-Diabetic Neuropathies, pubmed-meshheading:2167042-Environmental Exposure, pubmed-meshheading:2167042-Female, pubmed-meshheading:2167042-Humans, pubmed-meshheading:2167042-Male, pubmed-meshheading:2167042-Middle Aged, pubmed-meshheading:2167042-Models, Statistical, pubmed-meshheading:2167042-Peripheral Nervous System Diseases, pubmed-meshheading:2167042-Reference Values, pubmed-meshheading:2167042-Regression Analysis, pubmed-meshheading:2167042-Reproducibility of Results, pubmed-meshheading:2167042-Sensory Thresholds, pubmed-meshheading:2167042-Touch, pubmed-meshheading:2167042-Vibration
pubmed:articleTitle
Vibrotactile threshold measurement for detecting neurotoxicity: reliability and determination of age- and height-standardized normative values.
pubmed:affiliation
Department of Community Medicine, Mount Sinai School of Medicine, New York, New York.
pubmed:publicationType