Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
3
|
pubmed:dateCreated |
1990-11-5
|
pubmed:abstractText |
Scrub typhus is a major cause of febrile illness throughout the Asia-Pacific region. It is commonly undiagnosed, partly because of the lack of a simple, reliable diagnostic test which can be used in clinical laboratories. The indirect immunoperoxidase technique, configured into a test kit, was provided to technicians who were trained in its use. They used the kit during a 2 year field trial in their respective clinical hospital laboratories throughout Malaysia. In an evaluation using 1,722 consecutive sera tested in those laboratories, the kit was found to have a median sensitivity for IgG detection of 0.85 (range 0.33-0.95), a median specificity of 0.94 (range 0.88-1.00), reproducibility of 0.86, and efficiency of 0.92 when compared to the reference laboratory. In a proficiency survey in which 10 laboratories received 3 coded test samples, all but 2 laboratories had results within 1 dilution of the reference laboratory in quantitating specific IgG, whereas 7 laboratories were within 1 dilution in quantitating IgM. The shelf life of the kit was at least 1 year at 4 degrees C.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
AIM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Sep
|
pubmed:issn |
0002-9637
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
43
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
301-7
|
pubmed:dateRevised |
2007-11-15
|
pubmed:meshHeading |
pubmed-meshheading:2121057-Antibodies, Bacterial,
pubmed-meshheading:2121057-Evaluation Studies as Topic,
pubmed-meshheading:2121057-Humans,
pubmed-meshheading:2121057-Immunoenzyme Techniques,
pubmed-meshheading:2121057-Immunoglobulin G,
pubmed-meshheading:2121057-Immunoglobulin M,
pubmed-meshheading:2121057-Orientia tsutsugamushi,
pubmed-meshheading:2121057-Predictive Value of Tests,
pubmed-meshheading:2121057-Preservation, Biological,
pubmed-meshheading:2121057-Reagent Kits, Diagnostic,
pubmed-meshheading:2121057-Reproducibility of Results,
pubmed-meshheading:2121057-Scrub Typhus
|
pubmed:year |
1990
|
pubmed:articleTitle |
Multi-laboratory evaluation of a scrub typhus diagnostic kit.
|
pubmed:affiliation |
U.S. Army Medical Research Unit, Institute for Medical Research, Kuala Lumpur, Malaysia.
|
pubmed:publicationType |
Journal Article,
Research Support, U.S. Gov't, Non-P.H.S.
|