This study is an evaluation of the diagnostic accuracy of gadolinium-enhanced computed tomography pulmonary angiography (CTPA) for the detection of pulmonary embolism (PE) in comparison with iodine-enhanced CTPA. PE was induced in five anesthetized pigs by administration of blood clots through an 11-F catheter inside the jugular vein. Animals underwent CTPA in breathhold with i.v. bolus injection of 50 ml gadopentetate dimeglumine (0.4 mmol/kg, 4 ml/s). Subsequently, CTPA was performed using the same imaging parameters but under administration of 70 ml nonionic iodinated contrast material (400 mg/ml, 4 ml/s). All images were reconstructed with 1 mm slice thickness. A consensus readout of the iodium-enhanced CTPAs by both radiologists served as reference standard. Gadolinium-enhanced CTPAs were evaluated independently by two experienced radiologists, and differences in detection rate between both contrast agents were assessed on a per embolus basis using the Wilcoxon signed-rank test. Interobserver agreement was determined by calculation of ? values. PE was diagnosed independently by both readers in all five pigs by the use of gadolinium-enhanced CTPA. Out of 60 pulmonary emboli detected in the iodine-enhanced scans, 47 (78.3%; reader 1) and 44 (62.8%; reader 2) emboli were detected by the use of gadolinium. All 13 (100%) emboli in lobar arteries (by both readers) and 26 (reader 1) and 25 (reader 2) out of 27 emboli (96.3% and 92.6%) in segmental arteries were detected by the use of the gadolinium-enhanced CTPA. In subsegmental arteries, only 8 (40%; reader 1) and 6 (30%; reader 2) out of 20 emboli were detected by the gadolinium-enhanced CTPA. By comparing both scans on a per vessel basis (Wilcoxon test), Gd-enhanced CTPA was significantly inferior in emboli detection on subsegmental level (P?<?0.0001). The interobserver agreement was excellent on lobar and segmental level (??=?1.0 and 0.93, respectively), whereas readers only reached moderate agreement for PE evaluation on subsegmental level (??=?0.56). Compared to conventional CTPA with iodinated contrast media, gadolinium-based contrast agents achieve an equivalent diagnostic accuracy in detection of PE down to segmental level. Gadolinium-enhanced CTPA may be considered as an alternative for the diagnostic workup of acute pulmonary embolism in patients with contraindications to iodinated contrast agents.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Jun
|
pubmed:issn |
1438-1435
|
pubmed:author | |
pubmed:issnType |
Electronic
|
pubmed:volume |
18
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
189-95
|
pubmed:meshHeading |
pubmed-meshheading:21136130-Angiography,
pubmed-meshheading:21136130-Animals,
pubmed-meshheading:21136130-Contrast Media,
pubmed-meshheading:21136130-Disease Models, Animal,
pubmed-meshheading:21136130-Gadolinium,
pubmed-meshheading:21136130-Iodine,
pubmed-meshheading:21136130-Pulmonary Embolism,
pubmed-meshheading:21136130-Swine,
pubmed-meshheading:21136130-Tomography, X-Ray Computed
|
pubmed:year |
2011
|
pubmed:articleTitle |
Intraindividual comparison of gadolinium- and iodine-enhanced 64-slice multidetector CT pulmonary angiography for the detection of pulmonary embolism in a porcine model.
|