Source:http://linkedlifedata.com/resource/pubmed/id/21115445
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
1-4
|
pubmed:dateCreated |
2011-3-31
|
pubmed:abstractText |
In the case of a radiological emergency situation, involving accidental human exposure, it is necessary to establish as soon as possible a dosimetry evaluation. In most cases, this evaluation is based on numerical representations and models of the victims. Unfortunately, personalised and realistic human representations are often unavailable for the exposed subjects. Hence, existing models like the 'Reference Man' representative of the average male individual are used. However, the accuracy of the treatment depends on the similarity of the phantom to the victim. The EquiVox platform (Research of Equivalent Voxel phantom) developed in this work uses the case-based reasoning principles to retrieve, from a set of existing phantoms, the most adapted one to represent the victim. This paper introduces the EquiVox platform and gives the example of in vivo lung monitoring optimisation to prove its efficiency in choosing the right model. It also presents the artificial neural network tools being developed to adapt the model to the victim.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Mar
|
pubmed:issn |
1742-3406
|
pubmed:author | |
pubmed:issnType |
Electronic
|
pubmed:volume |
144
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
564-70
|
pubmed:meshHeading |
pubmed-meshheading:21115445-Algorithms,
pubmed-meshheading:21115445-Disaster Planning,
pubmed-meshheading:21115445-Humans,
pubmed-meshheading:21115445-Magnetic Resonance Imaging,
pubmed-meshheading:21115445-Male,
pubmed-meshheading:21115445-Models, Statistical,
pubmed-meshheading:21115445-Models, Theoretical,
pubmed-meshheading:21115445-Neural Networks (Computer),
pubmed-meshheading:21115445-Phantoms, Imaging,
pubmed-meshheading:21115445-Radiation Monitoring,
pubmed-meshheading:21115445-Radiation Protection,
pubmed-meshheading:21115445-Radioactive Hazard Release,
pubmed-meshheading:21115445-Radiometry,
pubmed-meshheading:21115445-Tomography, X-Ray Computed
|
pubmed:year |
2011
|
pubmed:articleTitle |
Development of a new CBR-based platform for human contamination emergency situations.
|
pubmed:affiliation |
French Institute of Radiological Protection and Nuclear Safety, Internal Dose Assessment Laboratory, DRPH/SDI/LEDI, BP-17, F-92262 Fontenay-aux-Roses, France.
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't
|