This paper gives performance evaluation of wearable wireless body area networks (WBANs) during walking motion. In order to evaluate the performance, received signal strength (RSS), packet error rate (PER), and bit error rate (BER) are measured in an anechoic chamber and an office room. This measurement is conducted in the frequency band of 444.5 and 2450 MHz by using GFSK signal with symbol rate of 1 MHz. The results show that in the anechoic chamber the WBAN using the 444.5 MHz enables to provide error-free communication, on the other hand, the WBAN operated in the 2450 MHz faces packet errors. Measurement results in the office room give comparable performance between these frequencies. From these observations, the use of 2450 MHz for wearable WBANs needs reflection waves in order to compensate a shadowing effect caused by the human body using the WBAN.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:issn
1557-170X
pubmed:author
pubmed:issnType
Print
pubmed:volume
2010
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
370-3
pubmed:meshHeading
pubmed:year
2010
pubmed:articleTitle
Performance evaluation of wearable wireless body area networks during walking motions in 444.5 MHz and 2450 MHz.
pubmed:affiliation
Medical ICT Group, National Institute of Information and Communications Technology (NICT), 3-4 Hikarino-oka, Kanagawa, 2390847 Japan. takizawa@nict.go.jp