Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:21076727rdf:typepubmed:Citationlld:pubmed
pubmed-article:21076727lifeskim:mentionsumls-concept:C0039070lld:lifeskim
pubmed-article:21076727lifeskim:mentionsumls-concept:C0021102lld:lifeskim
pubmed-article:21076727lifeskim:mentionsumls-concept:C1706211lld:lifeskim
pubmed-article:21076727lifeskim:mentionsumls-concept:C0180307lld:lifeskim
pubmed-article:21076727lifeskim:mentionsumls-concept:C0007961lld:lifeskim
pubmed-article:21076727lifeskim:mentionsumls-concept:C1546426lld:lifeskim
pubmed-article:21076727lifeskim:mentionsumls-concept:C1548280lld:lifeskim
pubmed-article:21076727pubmed:issue9lld:pubmed
pubmed-article:21076727pubmed:dateCreated2010-11-15lld:pubmed
pubmed-article:21076727pubmed:abstractTextIn patients with an implantable cardioverter defibrillator, empirical antitachycardia pacing/burst pacing (ATP) is associated with a significantly decreased rate of appropriate shocks. The use of ATP as first-line therapy in ventricular tachycardia promotes less pain and better quality of life because the number of shocks is reduced. Additionally, battery longevity is substantially increased with this strategy. Based on this, device manufacturers have developed new algorithms to optimize the use of ATP and shocks in patients with an implantable cardioverter defibrillator. The present report describes a case in which the use of one of these new algorithms was associated with a significant delay in tachycardia termination and, consequently, led to syncope.lld:pubmed
pubmed-article:21076727pubmed:languageenglld:pubmed
pubmed-article:21076727pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:21076727pubmed:citationSubsetIMlld:pubmed
pubmed-article:21076727pubmed:statusMEDLINElld:pubmed
pubmed-article:21076727pubmed:monthNovlld:pubmed
pubmed-article:21076727pubmed:issn1916-7075lld:pubmed
pubmed-article:21076727pubmed:authorpubmed-author:NanthakumarKu...lld:pubmed
pubmed-article:21076727pubmed:authorpubmed-author:NairKrishnaku...lld:pubmed
pubmed-article:21076727pubmed:authorpubmed-author:SubramanianAn...lld:pubmed
pubmed-article:21076727pubmed:authorpubmed-author:ChemelloDiego...lld:pubmed
pubmed-article:21076727pubmed:authorpubmed-author:WatkinsSheila...lld:pubmed
pubmed-article:21076727pubmed:issnTypeElectroniclld:pubmed
pubmed-article:21076727pubmed:volume26lld:pubmed
pubmed-article:21076727pubmed:ownerNLMlld:pubmed
pubmed-article:21076727pubmed:authorsCompleteYlld:pubmed
pubmed-article:21076727pubmed:paginatione341-3lld:pubmed
pubmed-article:21076727pubmed:dateRevised2011-11-1lld:pubmed
pubmed-article:21076727pubmed:meshHeadingpubmed-meshheading:21076727...lld:pubmed
pubmed-article:21076727pubmed:meshHeadingpubmed-meshheading:21076727...lld:pubmed
pubmed-article:21076727pubmed:meshHeadingpubmed-meshheading:21076727...lld:pubmed
pubmed-article:21076727pubmed:meshHeadingpubmed-meshheading:21076727...lld:pubmed
pubmed-article:21076727pubmed:meshHeadingpubmed-meshheading:21076727...lld:pubmed
pubmed-article:21076727pubmed:meshHeadingpubmed-meshheading:21076727...lld:pubmed
pubmed-article:21076727pubmed:meshHeadingpubmed-meshheading:21076727...lld:pubmed
pubmed-article:21076727pubmed:meshHeadingpubmed-meshheading:21076727...lld:pubmed
pubmed-article:21076727pubmed:meshHeadingpubmed-meshheading:21076727...lld:pubmed
pubmed-article:21076727pubmed:meshHeadingpubmed-meshheading:21076727...lld:pubmed
pubmed-article:21076727pubmed:meshHeadingpubmed-meshheading:21076727...lld:pubmed
pubmed-article:21076727pubmed:year2010lld:pubmed
pubmed-article:21076727pubmed:articleTitleImplantable cardioverter defibrillator: charge saver, not syncope saver!lld:pubmed
pubmed-article:21076727pubmed:affiliationThe Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, Toronto, Ontario.lld:pubmed
pubmed-article:21076727pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:21076727pubmed:publicationTypeCase Reportslld:pubmed
pubmed-article:21076727pubmed:publicationTypeResearch Support, Non-U.S. Gov'tlld:pubmed