Source:http://linkedlifedata.com/resource/pubmed/id/21072345
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
7
|
pubmed:dateCreated |
2010-11-12
|
pubmed:abstractText |
The development of an analytical method to quantify the major Cu, Fe and Zn-containing metalloproteins in mammalian plasma has been recently reported. This method is based on the separation of plasma proteins by size exclusion chromatography (SEC) followed by the on-line detection of the metalloproteins by an inductively coupled plasma atomic emission spectrometer (ICP-AES). To assess whether the mobile phase buffer can affect the SEC-ICP-AES-derived metalloproteome pattern, thawed rabbit plasma was analyzed using phosphate buffered saline (PBS)-buffer (0.15 M, pH 7.4), Tris-buffer (0.1 and 0.05 M, pH 7.4), Hepes-buffer (0.1 M, pH 7.4) or Mops-buffer (0.1 M, pH 7.4). In contrast to the Cu-specific chromatograms, the Fe and Zn-specific chromatograms that were obtained with Tris, Hepes and Mops-buffer were considerably different from those attained with PBS-buffer. The Tris, Hepes and Mops-buffer mediated redistribution of ~25% plasma Zn(2+) from <100 kDa to >100-600 kDa plasma proteins and to a smaller extent to a <10 kDa (Tris)(2)Zn(2+)-complex can be rationalized in terms of the abstraction of Zn(2+) from the weak binding site on albumin. In contrast, only Hepes and Mops-buffer redistributed ~20% of plasma Fe(3+) from the <100 kDa to the >600 kDa elution range. Based on these results and considering that the utilization of PBS-buffer has previously resulted in the detection of a number of Cu, Fe and Zn-containing metalloentities in rabbit plasma that was most consistent with literature data, this mobile phase buffer is recommended for metallomic studies regarding mammalian blood plasma.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical |
http://linkedlifedata.com/resource/pubmed/chemical/Buffers,
http://linkedlifedata.com/resource/pubmed/chemical/Copper,
http://linkedlifedata.com/resource/pubmed/chemical/HEPES,
http://linkedlifedata.com/resource/pubmed/chemical/Iron,
http://linkedlifedata.com/resource/pubmed/chemical/Metalloproteins,
http://linkedlifedata.com/resource/pubmed/chemical/Metals, Heavy,
http://linkedlifedata.com/resource/pubmed/chemical/Morpholines,
http://linkedlifedata.com/resource/pubmed/chemical/Proteome,
http://linkedlifedata.com/resource/pubmed/chemical/Tromethamine,
http://linkedlifedata.com/resource/pubmed/chemical/Zinc,
http://linkedlifedata.com/resource/pubmed/chemical/morpholinopropane sulfonic acid
|
pubmed:status |
MEDLINE
|
pubmed:month |
Jul
|
pubmed:issn |
1756-591X
|
pubmed:author | |
pubmed:issnType |
Electronic
|
pubmed:volume |
2
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
460-8
|
pubmed:dateRevised |
2011-9-16
|
pubmed:meshHeading |
pubmed-meshheading:21072345-Animals,
pubmed-meshheading:21072345-Buffers,
pubmed-meshheading:21072345-Chromatography, Gel,
pubmed-meshheading:21072345-Copper,
pubmed-meshheading:21072345-HEPES,
pubmed-meshheading:21072345-Iron,
pubmed-meshheading:21072345-Metalloproteins,
pubmed-meshheading:21072345-Metals, Heavy,
pubmed-meshheading:21072345-Morpholines,
pubmed-meshheading:21072345-Plasma,
pubmed-meshheading:21072345-Proteome,
pubmed-meshheading:21072345-Rabbits,
pubmed-meshheading:21072345-Spectrophotometry, Atomic,
pubmed-meshheading:21072345-Tromethamine,
pubmed-meshheading:21072345-Zinc
|
pubmed:year |
2010
|
pubmed:articleTitle |
Remarkable effect of mobile phase buffer on the SEC-ICP-AES derived Cu, Fe and Zn-metalloproteome pattern of rabbit blood plasma.
|
pubmed:affiliation |
Department of Chemistry, University of Calgary, 2500 University Drive NW, Calgary, Alberta, Canada.
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't
|