pubmed-article:21055955pubmed:abstractTextThe response of PADC was calculated by Monte Carlo simulation using MCNPX code. H, C and O recoils as well as nuclear reactions have been taken into account. The calculated results show important contribution to detection efficiency of PADC due to H, C and O recoils. The irradiated detectors with (241)Am-Be source and (241)Am-Be softened with a spherical polyethylene moderator were electrochemically etched. The paper presents the results of the experimental and Monte Carlo simulations, which are in a good agreement.lld:pubmed
pubmed-article:21055955pubmed:languageenglld:pubmed
pubmed-article:21055955pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:21055955pubmed:citationSubsetIMlld:pubmed
pubmed-article:21055955pubmed:statusMEDLINElld:pubmed
pubmed-article:21055955pubmed:monthFeblld:pubmed
pubmed-article:21055955pubmed:issn1872-9800lld:pubmed
pubmed-article:21055955pubmed:authorpubmed-author:TaheriMMlld:pubmed
pubmed-article:21055955pubmed:authorpubmed-author:AbdolmalekiPPlld:pubmed
pubmed-article:21055955pubmed:authorpubmed-author:KardanM RMRlld:pubmed
pubmed-article:21055955pubmed:authorpubmed-author:DeevbandM RMRlld:pubmed
pubmed-article:21055955pubmed:authorpubmed-author:KhosraviH RHRlld:pubmed
pubmed-article:21055955pubmed:copyrightInfoCopyright © 2010 Elsevier Ltd. All rights reserved.lld:pubmed
pubmed-article:21055955pubmed:issnTypeElectroniclld:pubmed
pubmed-article:21055955pubmed:volume69lld:pubmed
pubmed-article:21055955pubmed:ownerNLMlld:pubmed
pubmed-article:21055955pubmed:authorsCompleteYlld:pubmed
pubmed-article:21055955pubmed:pagination340-5lld:pubmed
pubmed-article:21055955pubmed:meshHeadingpubmed-meshheading:21055955...lld:pubmed
pubmed-article:21055955pubmed:meshHeadingpubmed-meshheading:21055955...lld:pubmed
pubmed-article:21055955pubmed:meshHeadingpubmed-meshheading:21055955...lld:pubmed
pubmed-article:21055955pubmed:year2011lld:pubmed
pubmed-article:21055955pubmed:articleTitleAn investigation on the response of PADC detectors to neutrons.lld:pubmed
pubmed-article:21055955pubmed:affiliationDepartment of Biophysics, Tarbiat Modarres University, P.O. Box 14155-6446, Tehran, Iran.lld:pubmed
pubmed-article:21055955pubmed:publicationTypeJournal Articlelld:pubmed