Source:http://linkedlifedata.com/resource/pubmed/id/21055955
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
2
|
pubmed:dateCreated |
2010-12-27
|
pubmed:abstractText |
The response of PADC was calculated by Monte Carlo simulation using MCNPX code. H, C and O recoils as well as nuclear reactions have been taken into account. The calculated results show important contribution to detection efficiency of PADC due to H, C and O recoils. The irradiated detectors with (241)Am-Be source and (241)Am-Be softened with a spherical polyethylene moderator were electrochemically etched. The paper presents the results of the experimental and Monte Carlo simulations, which are in a good agreement.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Feb
|
pubmed:issn |
1872-9800
|
pubmed:author | |
pubmed:copyrightInfo |
Copyright © 2010 Elsevier Ltd. All rights reserved.
|
pubmed:issnType |
Electronic
|
pubmed:volume |
69
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
340-5
|
pubmed:meshHeading | |
pubmed:year |
2011
|
pubmed:articleTitle |
An investigation on the response of PADC detectors to neutrons.
|
pubmed:affiliation |
Department of Biophysics, Tarbiat Modarres University, P.O. Box 14155-6446, Tehran, Iran.
|
pubmed:publicationType |
Journal Article
|