Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
7
pubmed:dateCreated
2011-6-16
pubmed:abstractText
The aim of this study is to review the experience of the clonidine suppression test in a regional endocrine centre and to compare the diagnostic sensitivity and specificity using various previous published criteria. The design used is retrospective study. The subjects include 56 patients in whom clonidine suppression tests had been performed from 1995 to 2000: 15 with phaeochromocytoma and 41 patients in whom the diagnosis was excluded using a combination of biochemical testing, abdominal computed tomography scanning and clinical follow-up. Plasma catecholamines were measured by high pressure liquid chromatography on basal samples and at hourly intervals for 3 h after the administration of clonidine 300 ?g orally and the following diagnostic criteria were applied: plasma noradrenaline+adrenaline>2.96 nmol l(-1) at 3 h post-clonidine or a baseline plasma adrenaline plus noradrenaline>11.82 nmol l(-1); plasma noradrenaline>2.96 nmol l(-1) at 3 h post-clonidine and plasma noradrenaline>2.96 nmol l(-1) and <50% fall in noradrenaline at 3 h post-clonidine. The results obtained is that mean plasma noradrenaline plus adrenaline fell across the test in 40/41 patients in the non-phaeochromocytoma patients and was lowest at 3 h (basal 2.28 ± 0.14 vs 1.36 ± 0.11 nmol l(-1), P<0.001). In the phaeochromocytoma group, clonidine had a variable effect on adrenaline plus noradrenaline levels with increases in 7/15. Using an abnormal result as a 3 h level of noradrenaline plus adrenaline>2.96 mmol l(-1) gave a sensitivity of 93% and specificity of 95%. When a 3 h noradrenaline>2.96 mmol l(-1) was used, sensitivity was 87% and specificity 95%. Using the former criteria, noradrenaline plus adrenaline>2.96 mmol l(-1), 1/15 in the phaeochromocytoma group had a normal result after clonidine suppression testing. Two of 41 in the non-phaeochromocytoma group had a false-positive result. Under carefully controlled conditions, the clonidine suppression test is well tolerated, safe and accurate for use in the investigation of patients with suspected phaeochromocytoma.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Jul
pubmed:issn
1476-5527
pubmed:author
pubmed:issnType
Electronic
pubmed:volume
25
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
451-6
pubmed:meshHeading
pubmed:year
2011
pubmed:articleTitle
Evaluation of the clonidine suppression test in the diagnosis of phaeochromocytoma.
pubmed:affiliation
Regional Centre for Endocrinology and Diabetes, Royal Victoria Hospital, Belfast, Northern Ireland, UK.
pubmed:publicationType
Journal Article, Research Support, Non-U.S. Gov't, Evaluation Studies