Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
3
pubmed:dateCreated
2010-2-19
pubmed:abstractText
Blood pressure measured before and after dialysis does not agree well with those recorded outside the dialysis unit. Whether recordings obtained outside the dialysis unit are of greater prognostic value than blood pressure obtained just before and after dialysis remains incompletely understood. Among 326 patients on long-term hemodialysis, blood pressure was self-measured at home for 1 week, over an interdialytic interval by ambulatory recording and before and after dialysis over 2 weeks. Over a mean follow-up of 32 (SD 20) months, 102 patients died (31%), yielding a crude mortality rate of 118/1000 patient years. Systolic but not diastolic blood pressure was found to be of prognostic importance. Adjusted and unadjusted multivariate analyses showed increasing quartiles of ambulatory and home systolic blood pressure to be associated with all-cause mortality (adjusted hazard ratios for increasing quartiles of ambulatory: 2.51, 3.43, 2.62; and for home blood pressure: 2.15, 1.7, 1.44). Mortality was lowest when home systolic blood pressure was between 120 to 130 mm Hg and ambulatory systolic blood pressure was between 110 to 120 mm Hg. Blood pressure recorded before and after dialysis was not statistically significant (P=0.17 for predialysis, and P=0.997 for postdialysis) in predicting mortality. Out-of-dialysis unit blood pressure measurement provided superior prognostic information compared to blood pressure within the dialysis unit (likelihood ratio test, P<0.05). Out-of-dialysis unit blood pressure among hemodialysis patients is prognostically more informative than that recorded just before and after dialysis. Therefore, the management of hypertension among these patients should focus on blood pressure recordings outside the dialysis unit.
pubmed:grant
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-10201019, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-10450117, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-10597759, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-10844617, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-11703618, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-12046035, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-12714851, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-12967694, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-15026401, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-15610223, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-15957127, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-16105064, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-16344376, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-16408134, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-16518349, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-16997057, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-17106312, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-17699236, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-17942773, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-18701616, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-19194283, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-19273737, http://linkedlifedata.com/resource/pubmed/commentcorrection/20083728-9794737
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Mar
pubmed:issn
1524-4563
pubmed:author
pubmed:issnType
Electronic
pubmed:volume
55
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
762-8
pubmed:dateRevised
2011-7-25
pubmed:meshHeading
pubmed-meshheading:20083728-Adult, pubmed-meshheading:20083728-Aged, pubmed-meshheading:20083728-Blood Pressure, pubmed-meshheading:20083728-Blood Pressure Monitoring, Ambulatory, pubmed-meshheading:20083728-Cohort Studies, pubmed-meshheading:20083728-Female, pubmed-meshheading:20083728-Follow-Up Studies, pubmed-meshheading:20083728-Humans, pubmed-meshheading:20083728-Hypertension, Renal, pubmed-meshheading:20083728-Kaplan-Meier Estimate, pubmed-meshheading:20083728-Kidney Failure, Chronic, pubmed-meshheading:20083728-Male, pubmed-meshheading:20083728-Middle Aged, pubmed-meshheading:20083728-Morbidity, pubmed-meshheading:20083728-Nonlinear Dynamics, pubmed-meshheading:20083728-Predictive Value of Tests, pubmed-meshheading:20083728-Prognosis, pubmed-meshheading:20083728-Proportional Hazards Models, pubmed-meshheading:20083728-Renal Dialysis
pubmed:year
2010
pubmed:articleTitle
Blood pressure and mortality among hemodialysis patients.
pubmed:affiliation
Indiana University, Richard L. Roudebush Veterans Administration Medical Center, Indianapolis, IN 46202, USA. ragarwal@iupui.edu
pubmed:publicationType
Journal Article, Research Support, N.I.H., Extramural