Source:http://linkedlifedata.com/resource/pubmed/id/20022723
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
3
|
pubmed:dateCreated |
2011-6-1
|
pubmed:abstractText |
Computed tomography (CT) was used for preoperative planning of minimal-invasive total hip arthroplasty (THA). 92 patients (50 males, 42 females, mean age 59.5 years) with a mean body-mass-index (BMI) of 26.5 kg/m(2) underwent 64-slice CT to depict the pelvis, the knee and the ankle in three independent acquisitions using combined x-, y-, and z-axis tube current modulation. Arthroplasty planning was performed using 3D-Hip Plan(®) (Symbios, Switzerland) and patient radiation dose exposure was determined. The effects of BMI, gender, and contralateral THA on the effective dose were evaluated by an analysis-of-variance. A process-cost-analysis from the hospital perspective was done. All CT examinations were of sufficient image quality for 3D-THA planning. A mean effective dose of 4.0 mSv (SD 0.9 mSv) modeled by the BMI (p<0.0001) was calculated. The presence of a contralateral THA (9/92 patients; p=0.15) and the difference between males and females were not significant (p=0.08). Personnel involved were the radiologist (4 min), the surgeon (16 min), the radiographer (12 min), and administrative personnel (4 min). A CT operation time of 11 min and direct per-patient costs of 52.80 € were recorded. Preoperative CT for THA was associated with a slight and justifiable increase of radiation exposure in comparison to conventional radiographs and low per-patient costs.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Jun
|
pubmed:issn |
1872-7727
|
pubmed:author | |
pubmed:copyrightInfo |
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
|
pubmed:issnType |
Electronic
|
pubmed:volume |
78
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
406-13
|
pubmed:meshHeading |
pubmed-meshheading:20022723-Arthroplasty, Replacement, Hip,
pubmed-meshheading:20022723-Female,
pubmed-meshheading:20022723-Germany,
pubmed-meshheading:20022723-Health Care Costs,
pubmed-meshheading:20022723-Humans,
pubmed-meshheading:20022723-Male,
pubmed-meshheading:20022723-Middle Aged,
pubmed-meshheading:20022723-Preoperative Care,
pubmed-meshheading:20022723-Prevalence,
pubmed-meshheading:20022723-Radiation Dosage,
pubmed-meshheading:20022723-Radiometry,
pubmed-meshheading:20022723-Tomography, X-Ray Computed
|
pubmed:year |
2011
|
pubmed:articleTitle |
Computed tomography for preoperative planning in minimal-invasive total hip arthroplasty: radiation exposure and cost analysis.
|
pubmed:affiliation |
Imaging Science Institute Charité Berlin, Robert-Koch-Platz 7, D-10115 Berlin, Germany. Alexander.Huppertz@charite.de
|
pubmed:publicationType |
Journal Article
|