Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:19692303rdf:typepubmed:Citationlld:pubmed
pubmed-article:19692303lifeskim:mentionsumls-concept:C0040300lld:lifeskim
pubmed-article:19692303lifeskim:mentionsumls-concept:C0023693lld:lifeskim
pubmed-article:19692303lifeskim:mentionsumls-concept:C0746961lld:lifeskim
pubmed-article:19692303lifeskim:mentionsumls-concept:C0442805lld:lifeskim
pubmed-article:19692303lifeskim:mentionsumls-concept:C0681916lld:lifeskim
pubmed-article:19692303lifeskim:mentionsumls-concept:C0750572lld:lifeskim
pubmed-article:19692303lifeskim:mentionsumls-concept:C0034108lld:lifeskim
pubmed-article:19692303lifeskim:mentionsumls-concept:C0599946lld:lifeskim
pubmed-article:19692303lifeskim:mentionsumls-concept:C0680844lld:lifeskim
pubmed-article:19692303lifeskim:mentionsumls-concept:C1515655lld:lifeskim
pubmed-article:19692303lifeskim:mentionsumls-concept:C0443131lld:lifeskim
pubmed-article:19692303pubmed:issue9lld:pubmed
pubmed-article:19692303pubmed:dateCreated2009-8-20lld:pubmed
pubmed-article:19692303pubmed:abstractTextA new technique was validated in vivo in reflectance pulse oximetry for measuring low oxygen saturations. Two pairs of light emitter/detector diodes allow for estimation of light attenuation (LA) in tissue, which is assumed to be responsible for the inaccuracy of pulse oximetry at less than 70 % arterial oxygen saturation. For validation, 17 newborn piglets were desaturated stepwise from 21 % to 1.25 % inspiratory oxygen concentration during general anesthesia, and arterial oxygen saturation was measured with the reflectance pulse oximeter adjusted for LA in tissue, with a standard transmission pulse oximeter and a hemoximeter. LA in tissue could be quantified and was different between snout and foreleg (probability level (p) < 0.05). At arterial oxygen saturations above 70 %, the bias between the methods was at 0 %-1 % and the variability 4 %-5 %. From 2 % to 100 % arterial oxygen saturation, the reflectance pulse oximeter estimated oxyhemoglobin saturation more accurately than a conventional transmission pulse oximeter (p < 0.05). At low oxygen saturations below 70 %, the bias and variability of the reflectance pulse oximeter calibration were closer to the hemoximeter measurements than the transmission pulse oximeter (p < 0.05). The variability of the reflectance pulse oximeter was slightly lower than the traditional oximeter by taking into account the LA in tissue (9 % versus 11 % -15 %, ns), and thus, the quality of the individual calibration lines improved (correlation coefficient, p < 0.05).lld:pubmed
pubmed-article:19692303pubmed:languageenglld:pubmed
pubmed-article:19692303pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:19692303pubmed:citationSubsetIMlld:pubmed
pubmed-article:19692303pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:19692303pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:19692303pubmed:statusMEDLINElld:pubmed
pubmed-article:19692303pubmed:monthSeplld:pubmed
pubmed-article:19692303pubmed:issn1558-2531lld:pubmed
pubmed-article:19692303pubmed:authorpubmed-author:AlbertMMlld:pubmed
pubmed-article:19692303pubmed:authorpubmed-author:ZwisslerBBlld:pubmed
pubmed-article:19692303pubmed:authorpubmed-author:KemmingGGlld:pubmed
pubmed-article:19692303pubmed:authorpubmed-author:Kisch-WedelHHlld:pubmed
pubmed-article:19692303pubmed:authorpubmed-author:BernreuterPPlld:pubmed
pubmed-article:19692303pubmed:issnTypeElectroniclld:pubmed
pubmed-article:19692303pubmed:volume56lld:pubmed
pubmed-article:19692303pubmed:ownerNLMlld:pubmed
pubmed-article:19692303pubmed:authorsCompleteYlld:pubmed
pubmed-article:19692303pubmed:pagination2271-9lld:pubmed
pubmed-article:19692303pubmed:meshHeadingpubmed-meshheading:19692303...lld:pubmed
pubmed-article:19692303pubmed:meshHeadingpubmed-meshheading:19692303...lld:pubmed
pubmed-article:19692303pubmed:meshHeadingpubmed-meshheading:19692303...lld:pubmed
pubmed-article:19692303pubmed:meshHeadingpubmed-meshheading:19692303...lld:pubmed
pubmed-article:19692303pubmed:meshHeadingpubmed-meshheading:19692303...lld:pubmed
pubmed-article:19692303pubmed:meshHeadingpubmed-meshheading:19692303...lld:pubmed
pubmed-article:19692303pubmed:meshHeadingpubmed-meshheading:19692303...lld:pubmed
pubmed-article:19692303pubmed:meshHeadingpubmed-meshheading:19692303...lld:pubmed
pubmed-article:19692303pubmed:meshHeadingpubmed-meshheading:19692303...lld:pubmed
pubmed-article:19692303pubmed:meshHeadingpubmed-meshheading:19692303...lld:pubmed
pubmed-article:19692303pubmed:meshHeadingpubmed-meshheading:19692303...lld:pubmed
pubmed-article:19692303pubmed:meshHeadingpubmed-meshheading:19692303...lld:pubmed
pubmed-article:19692303pubmed:meshHeadingpubmed-meshheading:19692303...lld:pubmed
pubmed-article:19692303pubmed:meshHeadingpubmed-meshheading:19692303...lld:pubmed
pubmed-article:19692303pubmed:year2009lld:pubmed
pubmed-article:19692303pubmed:articleTitleDoes the estimation of light attenuation in tissue increase the accuracy of reflectance pulse oximetry at low oxygen saturations in vivo?lld:pubmed
pubmed-article:19692303pubmed:affiliationClinic for Anaesthesiology, Ludwig- Maximilians-Universität Munich, D-81377 Munich, Germany. hille.kisch-wedel@med.uni-muenchen.delld:pubmed
pubmed-article:19692303pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:19692303pubmed:publicationTypeResearch Support, Non-U.S. Gov'tlld:pubmed