Source:http://linkedlifedata.com/resource/pubmed/id/19437429
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
12
|
pubmed:dateCreated |
2009-5-21
|
pubmed:abstractText |
A method for the determination of several household biocides in water by liquid chromatography/electrospray ionisation tandem mass spectrometry (LC/ESI-MS/MS) is presented. It permits the simultaneous determination of triclosan (TCS), triclocarban (TCC) and seven parabens, including the distinction between branched and linear isomers of propyl (i-PrP and n-PrP) and butyl parabens (i-BuP and n-BuP). Prior to LC/MS/MS, analytes are preconcentrated by solid-phase extraction (SPE) on Oasis HLB (60 mg) cartridges at natural sample pH and subsequently eluted with 4 mL of methanol. This simple SPE procedure provides extraction recoveries above 85% except for raw wastewater, where it falls to 65% for TCC. The performance of the method was tested with two triple-quadrupole LC/MS instruments from a low/mid and mid/high market range: a Varian 1200L and an API-4000. The latter system provided between 3 and 80 times lower limits of quantification (LOQs) than the first one, in the 0.08-0.44 ng/L range for surface water. Moreover, a comparison of matrix effects on both instruments showed a very different behaviour, particularly in the case of parabens. For these compounds signal suppression was observed in the 1200L instrument and signal enhancement with the 4000 instrument. As a result, different calibration approaches were chosen for them and this pointed to the need of matrix effect re-evaluation in method transfer between different LC/MS systems. The application of the method to real samples showed the ubiquity of methyl paraben (MeP) and n-PrP (at the 1-6 microg/L in raw wastewater) and the coexistence of i-BuP and n-BuP at similar levels (ca. 100-200 ng/L in raw wastewater).
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical |
http://linkedlifedata.com/resource/pubmed/chemical/Carbanilides,
http://linkedlifedata.com/resource/pubmed/chemical/Parabens,
http://linkedlifedata.com/resource/pubmed/chemical/Triclosan,
http://linkedlifedata.com/resource/pubmed/chemical/Water Pollutants, Chemical,
http://linkedlifedata.com/resource/pubmed/chemical/triclocarban
|
pubmed:status |
MEDLINE
|
pubmed:month |
Jun
|
pubmed:issn |
1097-0231
|
pubmed:author | |
pubmed:copyrightInfo |
Copyright (c) 2009 John Wiley & Sons, Ltd.
|
pubmed:issnType |
Electronic
|
pubmed:volume |
23
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
1756-66
|
pubmed:meshHeading |
pubmed-meshheading:19437429-Carbanilides,
pubmed-meshheading:19437429-Chromatography, Liquid,
pubmed-meshheading:19437429-Parabens,
pubmed-meshheading:19437429-Spectrometry, Mass, Electrospray Ionization,
pubmed-meshheading:19437429-Tandem Mass Spectrometry,
pubmed-meshheading:19437429-Triclosan,
pubmed-meshheading:19437429-Water Pollutants, Chemical
|
pubmed:year |
2009
|
pubmed:articleTitle |
Simultaneous determination of parabens, triclosan and triclocarban in water by liquid chromatography/electrospray ionisation tandem mass spectrometry.
|
pubmed:affiliation |
Department of Analytical Chemistry, Nutrition and Food Sciences, IIAA - Institute for Food Analysis and Research, University of Santiago de Compostela, 15782 Santiago de Compostela, Spain.
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't,
Evaluation Studies
|