pubmed:abstractText
Fourier transform ion cyclotron resonance mass spectrometry has the ability to realize exceptional mass measurement accuracy (MMA); MMA is one of the most significant attributes of mass spectrometric measurements as it affords extraordinary molecular specificity. However, due to space-charge effects, the achievable MMA significantly depends on the total number of ions trapped in the ICR cell for a particular measurement, as well as relative ion abundance of a given species. Artificial neural network calibration in conjunction with automatic gain control (AGC) is utilized in these experiments to formally account for the differences in total ion population in the ICR cell between the external calibration spectra and experimental spectra. In addition, artificial neural network calibration is used to account for both differences in total ion population in the ICR cell as well as relative ion abundance of a given species, which also affords mean MMA values at the parts-per-billion level.
pubmed:grant
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-10790845, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-11014449, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-11217775, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-11305659, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-11777206, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-14632135, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-15205369, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-15253445, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-15694774, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-15792715, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-15828774, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-16037072, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-16185891, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-16406561, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-16934995, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-16979902, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-17539605, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-18267874, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-3172241, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-7764850, http://linkedlifedata.com/resource/pubmed/commentcorrection/19362012-8130640
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Jul
pubmed:issn
1879-1123
pubmed:author
pubmed:issnType
Electronic
pubmed:volume
20
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
1303-10
pubmed:dateRevised
2010-9-24
pubmed:meshHeading
pubmed:year
2009
pubmed:articleTitle
Utilizing artificial neural networks in MATLAB to achieve parts-per-billion mass measurement accuracy with a fourier transform ion cyclotron resonance mass spectrometer.
pubmed:affiliation
W. M. Keck FT-ICR Mass Spectrometry Laboratory, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, USA.
pubmed:publicationType