pubmed:abstractText
Splenoportography was performed upon 195 pediatric patients, including 137 by conventional technique and 58 by digital subtraction technique. The results obtained were compared, and it was found that the percentage of diagnosis of spontaneous splenorenal shunt was higher with digital than with conventional technique. In conclusion digital technique is a more sensitive and safer method than the conventional method.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Sep
pubmed:issn
0003-3197
pubmed:author
pubmed:issnType
Print
pubmed:volume
42
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
754-9
pubmed:dateRevised
2006-11-15
pubmed:meshHeading
pubmed:year
1991
pubmed:articleTitle
A digital splenoportography: more sensitive method of detecting spontaneous splenorenal shunt.
pubmed:affiliation
Radiology Department, Hacettepe University School of Medicine, Ankara, Turkey.
pubmed:publicationType
Journal Article, Comparative Study