Source:http://linkedlifedata.com/resource/pubmed/id/19233748
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
13
|
pubmed:dateCreated |
2009-4-13
|
pubmed:abstractText |
1,3-Butadiene is used in the production of synthetic rubber and is also a widespread environmental pollutant, produced by car exhaust, heating and cigarette smoke. According to IARC it is probably carcinogenic to humans. A method was developed and validated for the quantification in human urine of 1,2-dihydroxybutyl mercapturic acid, a butadiene metabolite for which the American Conference of Governmental Hygienists suggests a biological exposure index of 2500 microg/L. Solid phase extraction was used for analyte extraction and HPLC-MS/MS for detection. The calibration range from 20 to 2500 microg/L required the use of polynomial calibration curves, and the performance of the analytical method was tested according to an international validation guideline. Accuracy was never less than 85%, precision always higher than 15% and the LOD 3.6 microg/L. The method was applied to 33 non-smokers, non-occupationally exposed to butadiene, and gave urinary concentrations between 16 and 599 microg/L.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
May
|
pubmed:issn |
1873-376X
|
pubmed:author | |
pubmed:issnType |
Electronic
|
pubmed:day |
1
|
pubmed:volume |
877
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
1388-93
|
pubmed:meshHeading |
pubmed-meshheading:19233748-Acetylcysteine,
pubmed-meshheading:19233748-Butadienes,
pubmed-meshheading:19233748-Calibration,
pubmed-meshheading:19233748-Chromatography, High Pressure Liquid,
pubmed-meshheading:19233748-Humans,
pubmed-meshheading:19233748-Quality Control,
pubmed-meshheading:19233748-Reproducibility of Results,
pubmed-meshheading:19233748-Sensitivity and Specificity,
pubmed-meshheading:19233748-Tandem Mass Spectrometry,
pubmed-meshheading:19233748-Uncertainty
|
pubmed:year |
2009
|
pubmed:articleTitle |
Quantitative determination of the 1,3-butadiene urinary metabolite 1,2-dihydroxybutyl mercapturic acid by high-performance liquid chromatography/tandem mass spectrometry using polynomial calibration curves.
|
pubmed:affiliation |
Department of Environmental Medicine and Public Health, University of Padua, via Giustiniani 2, 35128 Padua, Italy.
|
pubmed:publicationType |
Journal Article,
Validation Studies
|