Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
2
pubmed:dateCreated
2009-2-9
pubmed:abstractText
Investigation of unexpected levels of impurities in Intron product has revealed the presence of low levels of impurities leached from the silicone tubing (Rehau RAU-SIK) on the Bosch filling line. In order to investigate the effect of these compounds (1a, 1b and 2) on humans, they were isolated identified and synthesized. They were extracted from the tubing by stirring in Intron placebo at room temperature for 72 h and were enriched on a reverse phase CHP-20P column, eluting with gradient aqueous ACN and were separated by HPLC. Structural elucidation of 1a, 1b and 2 by MS and NMR studies demonstrated them to be halogenated biphenyl carboxylic acids. The structures were confirmed by independent synthesis. Levels of extractable impurities in first filled vials of actual production are estimated to be in the range of 0.01-0.55 microg/vial for each leached impurity. Potential toxicity of these extractables does not represent a risk for patients under the conditions of clinical use.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Feb
pubmed:issn
0731-7085
pubmed:author
pubmed:issnType
Print
pubmed:day
20
pubmed:volume
49
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
327-32
pubmed:dateRevised
2011-11-17
pubmed:meshHeading
pubmed-meshheading:19150187-Buffers, pubmed-meshheading:19150187-Chemistry, Pharmaceutical, pubmed-meshheading:19150187-Chromatography, High Pressure Liquid, pubmed-meshheading:19150187-Drug Contamination, pubmed-meshheading:19150187-Freeze Drying, pubmed-meshheading:19150187-Humans, pubmed-meshheading:19150187-Hydrogen-Ion Concentration, pubmed-meshheading:19150187-Interferon-alpha, pubmed-meshheading:19150187-Magnetic Resonance Spectroscopy, pubmed-meshheading:19150187-Mass Spectrometry, pubmed-meshheading:19150187-Molecular Structure, pubmed-meshheading:19150187-Organic Chemicals, pubmed-meshheading:19150187-Powders, pubmed-meshheading:19150187-Quality Control, pubmed-meshheading:19150187-Recombinant Proteins, pubmed-meshheading:19150187-Silicones, pubmed-meshheading:19150187-Temperature, pubmed-meshheading:19150187-Time Factors
pubmed:year
2009
pubmed:articleTitle
Isolation, structural determination, synthesis and quantitative determination of impurities in Intron-A, leached from a silicone tubing.
pubmed:affiliation
Structural Chemistry Department, Schering Plough Research Institute, Kenilworth, NJ 07033, USA.
pubmed:publicationType
Journal Article