pubmed:abstractText
A simple method based on capillary electrophoresis with a capacitively coupled contactless conductivity detector (CE-C(4)D) was developed for the determination of suxamethonium (SUX) in a pharmaceutical formulation. A hydro-organic mixture, consisting of 100mM Tris-acetate buffer at pH 4.2 and acetonitrile (90:10, v/v), was selected as background electrolyte (BGE). The applied voltage was 30kV, and the sample injection was performed in the hydrodynamic mode. All analyses were carried out in a fused silica capillary with an internal diameter of 50 microm and a total length of 64.5cm. Under these conditions, a complete separation between SUX, sodium ions and the main degradation products (choline) was achieved in less than 4min. The presence of acetonitrile in the BGE allowed a reduction of SUX adsorption on the capillary wall. The CE-C(4)D method was validated, and trueness values between 98.8% and 101.1% were obtained with repeatability and intermediate precision values of 0.7-1.3% and 1.2-1.6%, respectively. Therefore, this method was found appropriate for controlling pharmaceutical formulations containing suxamethonium and degradation products.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Feb
pubmed:issn
0731-7085
pubmed:author
pubmed:issnType
Print
pubmed:day
20
pubmed:volume
49
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
333-7
pubmed:meshHeading
pubmed-meshheading:19121913-Acetic Acid, pubmed-meshheading:19121913-Acetonitriles, pubmed-meshheading:19121913-Adsorption, pubmed-meshheading:19121913-Buffers, pubmed-meshheading:19121913-Chemistry, Pharmaceutical, pubmed-meshheading:19121913-Choline, pubmed-meshheading:19121913-Electric Conductivity, pubmed-meshheading:19121913-Electricity, pubmed-meshheading:19121913-Electrolytes, pubmed-meshheading:19121913-Electrophoresis, Capillary, pubmed-meshheading:19121913-Hydrogen-Ion Concentration, pubmed-meshheading:19121913-Ions, pubmed-meshheading:19121913-Molecular Structure, pubmed-meshheading:19121913-Neuromuscular Depolarizing Agents, pubmed-meshheading:19121913-Reference Standards, pubmed-meshheading:19121913-Reproducibility of Results, pubmed-meshheading:19121913-Succinylcholine, pubmed-meshheading:19121913-Temperature, pubmed-meshheading:19121913-Time Factors, pubmed-meshheading:19121913-Tromethamine
pubmed:year
2009
pubmed:articleTitle
Determination of suxamethonium in a pharmaceutical formulation by capillary electrophoresis with contactless conductivity detection (CE-C(4)D).
pubmed:affiliation
Pharmacy, University Hospitals of Geneva , Geneva, Switzerland.
pubmed:publicationType
Journal Article