2008-10-13
|
pubmed:abstractText |
The presence of protein in hypertensive disorders of pregnancy is a sign of a worsening condition and thus requires early intervention to prevent adverse consequences. Accurate assessment of proteinuria in patients with pre-eclampsia will ensure prompt and timely intervention to reduce or prevent the maternal and perinatal morbidity and mortality associated with pre-eclampsia. This study compared the reliability and validity of the more rapid diagnostic tests, such as the dipstick, 2-h and 12-h protein estimations with the 24-h protein. The result of the dipstick, 2-h and 12-h urine were also compared with the 24-h urine results using confidence interval (CI) for proportions with a value of p < 0.05 considered significant (CI 95%). When compared with the gold standard, there was a high degree of correlation between the 2-h (p = 0.244, CI 95%) and 12-h (p < 0.0255, CI 95%) with the 24-h sample in the quantification of proteinuria in women with pre-eclampsia. The most sensitive and specific test was the 12-h protein estimation, (89%) and (93%), respectively. The least sensitive and specific test was the dipstick test; (81%) and (47%), respectively. The 12-h protein estimation test had the highest positive predictive value (84%). The 12-h protein test also had the lowest false positive rate (12%) and false negative rates (11%), respectively. The most accurate test was the 12-h protein estimation (88%). The dipstick tests were however much cheaper and the results were faster. It is recommended that routine rapid quantisation of proteinuria in patients with pre-eclampsia be done using either the 2-h or 12-h urine sample.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Jul
|
pubmed:issn |
1364-6893
|
pubmed:author | |
pubmed:issnType |
Electronic
|
pubmed:volume |
28
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
496-500
|
pubmed:meshHeading |
pubmed-meshheading:18850422-Adult,
pubmed-meshheading:18850422-Female,
pubmed-meshheading:18850422-Humans,
pubmed-meshheading:18850422-Pre-Eclampsia,
pubmed-meshheading:18850422-Pregnancy,
pubmed-meshheading:18850422-Proteinuria,
pubmed-meshheading:18850422-Reagent Strips,
pubmed-meshheading:18850422-Reproducibility of Results,
pubmed-meshheading:18850422-Sensitivity and Specificity,
pubmed-meshheading:18850422-Time Factors,
pubmed-meshheading:18850422-Urine
|
pubmed:year |
2008
|
pubmed:articleTitle |
Accuracy of urine dipsticks, 2-h and 12-h urine collections for protein measurement as compared with the 24-h collection.
|
pubmed:affiliation |
Department of Obstetrics and Gynecology, Irrua Specialist Teaching Hospital, Irrua, Edo State, Nigeria.
|
pubmed:publicationType |
Journal Article,
Comparative Study
|