Source:http://linkedlifedata.com/resource/pubmed/id/18638586
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
3
|
pubmed:dateCreated |
2008-7-21
|
pubmed:abstractText |
Previous studies have demonstrated that microvolt T-wave alternans (MTWA) screening effectively risk-stratifies patients with ischemic cardiomyopathy. Whether the prognostic utility of MTWA diminishes over 3 years of follow-up remains unknown. In this study, a prospective cohort of 768 patients with ischemic cardiomyopathy (left ventricular ejection fraction <35%) and no previous sustained ventricular arrhythmia was developed, of whom 514 (67%) screened MTWA nonnegative (positive and indeterminate). The mean follow-up period was 18 +/- 11 months. The primary end point was all-cause mortality and appropriate implantable cardioverter-defibrillator shocks. Stratified Cox regression analyses (by implantable cardioverter-defibrillator status) estimated the predictive power of MTWA within each year of follow-up and determined whether this diminished over time. There were 99 deaths (MTWA negative: 21 [8.3%]; MTWA nonnegative: 78 [15.2%]) and 33 appropriate implantable cardioverter-defibrillator shocks (MTWA negative: 3 [4.0%]; MTWA nonnegative: 30 [9.5%]). After multivariate adjustment, a nonnegative MTWA test result was associated with a greater than twofold increased risk for events in each of the 3 years of follow-up (year 1: stratified hazard ratio 2.19, 95% confidence interval 1.10 to 4.34, p = 0.03; year 2: stratified hazard ratio 3.36, 95% confidence interval 1.28 to 8.83, p = 0.01; year 3: stratified hazard ratio 2.06, 95% confidence interval 0.81 to 5.22, p = 0.13). There were no significant interactions between the time periods (year 1 vs year 2: p = 0.47; year 1 vs year 3: p = 0.92). In conclusion, MTWA reliably and consistently predicts mortality and arrhythmic risk throughout the first 2 to 3 years of follow-up. Although these findings need further validation, they suggest that rescreening with MTWA may not need to be performed more frequently than once every 2 years.
|
pubmed:commentsCorrections | |
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
AIM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Aug
|
pubmed:issn |
0002-9149
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
1
|
pubmed:volume |
102
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
280-4
|
pubmed:dateRevised |
2008-11-6
|
pubmed:meshHeading |
pubmed-meshheading:18638586-Aged,
pubmed-meshheading:18638586-Cardiomyopathies,
pubmed-meshheading:18638586-Defibrillators, Implantable,
pubmed-meshheading:18638586-Electrocardiography,
pubmed-meshheading:18638586-Female,
pubmed-meshheading:18638586-Follow-Up Studies,
pubmed-meshheading:18638586-Humans,
pubmed-meshheading:18638586-Male,
pubmed-meshheading:18638586-Myocardial Ischemia,
pubmed-meshheading:18638586-Regression Analysis
|
pubmed:year |
2008
|
pubmed:articleTitle |
Usefulness of microvolt T-wave alternans to predict outcomes in patients with ischemic cardiomyopathy beyond one year.
|
pubmed:affiliation |
Mid-America Heart Institute and University of Missouri, Kansas City, Missouri, USA. paul1chan@yahoo.com
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't,
Research Support, N.I.H., Extramural
|