Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
2
pubmed:dateCreated
2008-6-23
pubmed:abstractText
This paper reports a comparison of the gait patterns of trans-femoral amputees using a single-axis prosthetic knee that coordinates ankle and knee flexions (Proteor's Hydracadence system) with the gait patterns of patients using other knee joints without a knee-ankle link and the gait patterns of individuals with normal gait. The two patient groups were composed of 11 male trans-femoral amputees: six patients had the Hydracadence joint (Group 1) and five patients had other prosthetic knees (Group 2). The reference group was made up of 23 normal volunteers (Group 3). In this work, trunk, hip, knee, and ankle 3-D motion was assessed using the VICON system. Kinetic data were collected by two AMTI force plates, and the knee moment was calculated via the 3-D equilibrium equations. An original questionnaire was used to assess the participants' activity level and clinical background. The results reveal that, during stance, all knee types guaranteed security. After heel strike, the plantar flexion of the ankle enabled by the Hydracadence prosthesis seems to increase stability. During swing phase, hip and knee sagittal motion was nearly the same in both Group 1 and Group 2. By contrast, hallux and sole vertical positions were significantly higher in Group 1 than in Group 2; thus, it seems the link between the ankle joint and the knee joint makes foot clearance easier. No alteration of the lateral bending of the trunk was observed. The protocol proposed in this paper allows a functional comparison between prosthetic components by combining clinical data with objective 3-D kinematic and kinetic information. It might help to determine which prosthetic knees are best for a specific patient.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Jun
pubmed:issn
1746-1553
pubmed:author
pubmed:issnType
Electronic
pubmed:volume
32
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
201-18
pubmed:meshHeading
pubmed:year
2008
pubmed:articleTitle
Functional gait analysis of trans-femoral amputees using two different single-axis prosthetic knees with hydraulic swing-phase control: Kinematic and kinetic comparison of two prosthetic knees.
pubmed:affiliation
Laboratoire de Biomécanique ENSAM AM ParisTech, France. emilie.sapin@gadz.org
pubmed:publicationType
Journal Article, Comparative Study, Research Support, Non-U.S. Gov't