pubmed:abstractText
The authors describe a dual tube/detector micro-computed tomography (micro-CT) system that has the potential to improve temporal resolution and material contrast in small animal imaging studies. To realize this potential, it is necessary to precisely calibrate the geometry of a dual micro-CT system to allow the combination of projection data acquired with each individual tube/detector in a single reconstructed image. The authors present a geometric calibration technique that uses multiple projection images acquired with the two imaging chains while rotating a phantom containing a vertical array of regularly spaced metallic beads. The individual geometries of the imaging chains are estimated from the phantom projection images using analytical methods followed by a refinement procedure based on nonlinear optimization. The geometric parameters are used to create the cone beam projection matrices required by the reconstruction process for each imaging chain. Next, a transformation between the two projection matrices is found that allows the combination of projection data in a single reconstructed image. The authors describe this technique, test it with a series of computer simulations, and then apply it to data collected from their dual tube/detector micro-CT system. The results demonstrate that the proposed technique is accurate, robust, and produces images free of misalignment artifacts.
pubmed:grant
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-10659735, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-11021683, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-11098919, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-11385756, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-11695767, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-14552575, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-15651608, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-15651615, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-15895580, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-16105509, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-16507552, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-16827495, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-16872077, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-17255374, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-17555236, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-17558678, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-17926967, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-8306301, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-8346283, http://linkedlifedata.com/resource/pubmed/commentcorrection/18561657-9725140
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
May
pubmed:issn
0094-2405
pubmed:author
pubmed:issnType
Print
pubmed:volume
35
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
1820-9
pubmed:dateRevised
2011-9-26
pubmed:meshHeading
pubmed:year
2008
pubmed:articleTitle
Geometric calibration for a dual tube/detector micro-CT system.
pubmed:affiliation
Center for In Vivo Microscopy, Box 3302, Duke University Medical Center, Durham, North Carolina 27710, USA.
pubmed:publicationType
Journal Article, Research Support, N.I.H., Extramural