Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
1
pubmed:dateCreated
1991-8-23
pubmed:abstractText
The ISO 7243 heat stress standard based on the wet bulb globe temperature (WBGT) heat stress index and the analytical standard proposal ISO/DIS 7933 were evaluated in eight physically trained and eight untrained, unacclimated men during prolonged light exercise carried out while wearing industrial work clothing. The exercise tests were done in a thermoneutral (20 degrees C/40%), a warm humid (30 degrees C/80% humidity), and a hot dry (40 degrees C/20% humidity) environment. Both of the standards were effective in predicting the excessive thermal strain observed in the dry and humid heat (WBGT, 28 degrees C). In dry heat, neither of the standards took into account the higher sweating capacities of the physically trained men. The large inter-individual variability in the physiological responses to heat stress questioned the calculations of definite allowable exposure times (ISO/DIS 7933).
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:issn
0340-0131
pubmed:author
pubmed:issnType
Print
pubmed:volume
63
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
39-41
pubmed:dateRevised
2008-11-21
pubmed:meshHeading
pubmed:year
1991
pubmed:articleTitle
An evaluation of heat stress indices (ISO 7243, ISO/DIS 7933) in the prediction of heat strain in unacclimated men.
pubmed:affiliation
Institute of Occupational Health, Laajaniityntie, Vantaa, Finland.
pubmed:publicationType
Journal Article