pubmed:abstractText
This study analyses the reliability of an on-site MBR system for greywater treatment and reuse. To achieve this goal simulation was performed based on the IWA ASM1 model which was adapted to describe biological and physical mechanisms for MBR greywater treatment based systems. Model results were found to agree well with experimental data from an on site pilot greywater treatment plant, after which the calibrated model was used in a Monte Carlo mode for generating statistical data on the MBR system performance under different scenarios of failures and inflow loads variations. Effluents quality and their associated risks were successfully estimated.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:issn
0273-1223
pubmed:author
pubmed:copyrightInfo
Copyright IWA Publishing 2008.
pubmed:issnType
Print
pubmed:volume
57
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
1103-10
pubmed:meshHeading
pubmed:year
2008
pubmed:articleTitle
Assessment of the reliability of an on-site MBR system for greywater treatment and the associated aesthetic and health risks.
pubmed:affiliation
Faculty of Civil & Environmental Eng, Technion, Israel Institute of Technology, Haifa 32000, Israel. eranf@tx.technion.ac.il
pubmed:publicationType