Source:http://linkedlifedata.com/resource/pubmed/id/18367795
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
6
|
pubmed:dateCreated |
2008-3-27
|
pubmed:abstractText |
We investigated the role and the weight of the parameters involved in the intensity modulated radiation therapy (IMRT) optimization based on the generalized equivalent uniform dose (gEUD) method, for prostate and head-and-neck plans. We systematically varied the parameters (gEUDmax and weight) involved in the gEUD-based optimization of rectal wall and parotid glands. We found that the proper value of weight factor, still guaranteeing planning treatment volumes coverage, produced similar organs at risks dose-volume (DV) histograms for different gEUDmax with fixed a=1. Most of all, we formulated a simple relation that links the reference gEUDmax and the associated weight factor. As secondary objective, we evaluated plans obtained with the gEUD-based optimization and ones based on DV criteria, using the normal tissue complication probability (NTCP) models. gEUD criteria seemed to improve sparing of rectum and parotid glands with respect to DV-based optimization: the mean dose, the V40 and V50 values to the rectal wall were decreased of about 10%, the mean dose to parotids decreased of about 20-30%. But more than the OARs sparing, we underlined the halving of the OARs optimization time with the implementation of the gEUD-based cost function. Using NTCP models we enhanced differences between the two optimization criteria for parotid glands, but no for rectum wall.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Mar
|
pubmed:issn |
0031-9155
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
21
|
pubmed:volume |
53
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
1665-75
|
pubmed:meshHeading |
pubmed-meshheading:18367795-Head,
pubmed-meshheading:18367795-Humans,
pubmed-meshheading:18367795-Male,
pubmed-meshheading:18367795-Neck,
pubmed-meshheading:18367795-Probability,
pubmed-meshheading:18367795-Prostate,
pubmed-meshheading:18367795-Radiation Dosage,
pubmed-meshheading:18367795-Radiobiology,
pubmed-meshheading:18367795-Radiotherapy, Intensity-Modulated,
pubmed-meshheading:18367795-Radiotherapy Dosage,
pubmed-meshheading:18367795-Radiotherapy Planning, Computer-Assisted,
pubmed-meshheading:18367795-Reproducibility of Results
|
pubmed:year |
2008
|
pubmed:articleTitle |
Role of the parameters involved in the plan optimization based on the generalized equivalent uniform dose and radiobiological implications.
|
pubmed:affiliation |
SC Laboratorio di Fisica Medica e Sistemi Esperti, Istituto Regina Elena, Roma, Italy. widesott@atrep.it
|
pubmed:publicationType |
Journal Article
|