Source:http://linkedlifedata.com/resource/pubmed/id/18293556
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
1
|
pubmed:dateCreated |
2008-2-25
|
pubmed:abstractText |
The effect of the energy dispersion of a quasi-monochromatic x-ray beam on the performance of a dual-energy x-ray imaging system is studied by means of Monte Carlo simulations using MCNPX (Monte Carlo N-Particle eXtended) version 2.6.0. In particular, the case of subtraction imaging at the iodine K-edge, suitable for angiographic imaging application, is investigated. The average energies of the two beams bracketing the iodine K-edge are set to the values of 31.2 and 35.6 keV corresponding to the ones obtained with a compact source based on a conventional x-ray tube and a mosaic crystal monochromator. The energy dispersion of the two beams is varied between 0 and 10 keV of full width at half-maximum (FWHM). The signal and signal-to-noise ratio produced in the simulated images by iodine-filled cavities (simulating patient vessels) drilled in a PMMA phantom are studied as a function of the x-ray energy dispersion. The obtained results show that, for the considered energy separation of 4.4 keV, no dramatic deterioration of the image quality is observed with increasing x-ray energy dispersion up to a FWHM of about 2.35 keV. The case of different beam energies is also investigated by means of fast simulations of the phantom absorption.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Jan
|
pubmed:issn |
0094-2405
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
35
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
13-24
|
pubmed:meshHeading |
pubmed-meshheading:18293556-Angiography, Digital Subtraction,
pubmed-meshheading:18293556-Computer Simulation,
pubmed-meshheading:18293556-Electrons,
pubmed-meshheading:18293556-Humans,
pubmed-meshheading:18293556-Iodine,
pubmed-meshheading:18293556-Monte Carlo Method,
pubmed-meshheading:18293556-Phantoms, Imaging,
pubmed-meshheading:18293556-Photons,
pubmed-meshheading:18293556-X-Rays
|
pubmed:year |
2008
|
pubmed:articleTitle |
Effect of x-ray energy dispersion in digital subtraction imaging at the iodine K-edge--a Monte Carlo study.
|