Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:dateCreated
2008-2-14
pubmed:abstractText
Parametric images generated from dynamic positron emission tomography (PET) studies are useful for presenting functional/biological information in the 3-dimensional space, but usually suffer from their high sensitivity to image noise. To improve the quality of these images, we proposed in this study a modified linear least square (LLS) fitting method named cLLS that incorporates a clustering-based spatial constraint for generation of parametric images from dynamic PET data of high noise levels. In this method, the combination of K-means and hierarchical cluster analysis was used to classify dynamic PET data. Compared with conventional LLS, cLLS can achieve high statistical reliability in the generated parametric images without incurring a high computational burden. The effectiveness of the method was demonstrated both with computer simulation and with a human brain dynamic FDG PET study. The cLLS method is expected to be useful for generation of parametric images from dynamic FDG PET study.
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-10329295, http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-11020827, http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-11091109, http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-11138696, http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-11295885, http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-117743, http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-11848713, http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-12725772, http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-14980551, http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-18215932, http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-1946602, http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-3485644, http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-6334095, http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-6822610, http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-6965568, http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-8417003, http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-8441024, http://linkedlifedata.com/resource/pubmed/commentcorrection/18273393-864466
pubmed:language
eng
pubmed:journal
pubmed:status
PubMed-not-MEDLINE
pubmed:issn
1687-4188
pubmed:author
pubmed:issnType
Print
pubmed:volume
2007
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
65641
pubmed:year
2007
pubmed:articleTitle
Clustering-based linear least square fitting method for generation of parametric images in dynamic FDG PET studies.
pubmed:affiliation
The Beijing City Key Lab of Medical Physics and Engineering, Peking University, Beijing 100871, China.
pubmed:publicationType
Journal Article