Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
12
pubmed:dateCreated
2007-12-27
pubmed:abstractText
Interest in estimating HIV-1 incidence using specimens obtained as part of cross-sectional surveys has led to the development of new methods to detect recent HIV-1 infection through the testing of a single anti-HIV-positive specimen. These assays are based on quantitative and qualitative differences in anti-HIV-1 antibodies between recent and long-standing infections. An ongoing vaccine preparedness study enrolled female sex workers in the Dominican Republic. Specimens from women found to be HIV positive at baseline were tested for recent HIV-1 infection using the detuned assay, avidity index, and BED-CEIA assay. An unweighted kappa statistic in pairwise comparisons was used to estimate the correlation of recent HIV-1 infection detection by the three methods. Nineteen (3.9%) of 482 women were positive for HIV-1 infection. The incidence of HIV infection was 1.4% [95% confidence interval (CI): 0.2, 5.3], 0.9%(95% CI: 0.1, 4.4), and 1.0%(95% CI: 0.1, 4.4) using detuned assay, avidity index, and BED-CEIA techniques, respectively. The overall agreement between both detuned assay and avidity index and detuned assay and BED-CEIA was 94%(kappa = 0.8, 95% CI; 0.3, 1.0). The correlation was highest between BED-CEIA and avidity index methods (100%; kappa = 1.0). All three methods performed similarly in detecting recent HIV-1 infection in this region dominated by clade B HIV-1 infection. Although incidence estimates were slightly higher using the detuned assay method, they were not significantly different. These assays may be of value in both clinical research and practice. The utility of individual assays for recent infection detection will depend upon operating characteristics, HIV-1 subtype limitations, and selection of appropriate assay cutoff values.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Dec
pubmed:issn
0889-2229
pubmed:author
pubmed:issnType
Print
pubmed:volume
23
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
1475-80
pubmed:meshHeading
pubmed:year
2007
pubmed:articleTitle
Comparison of methods to detect recent HIV type 1 infection in cross-sectionally collected specimens from a cohort of female sex workers in the Dominican Republic.
pubmed:affiliation
Merck Research Laboratories, West Point, Pennsylvania 19454, USA. swati_gupta@merck.com
pubmed:publicationType
Journal Article, Comparative Study, Research Support, Non-U.S. Gov't