pubmed:abstractText |
Automatic management of atrial stimulation by verification of atrial threshold (ACM) has recently been made feasible. We investigated circadian atrial threshold variability over the long term and the predictors of successful automatic atrial threshold measurement, in order to provide practical clues for programming ACM features, in such a way as to achieve daily threshold verification and > 99% effective atrial stimulation.
|
pubmed:language |
eng
|
pubmed:journal |
|
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Dec
|
pubmed:issn |
0147-8389
|
pubmed:author |
pubmed-author:ArgnaniSelinaS,
pubmed-author:BarbatoGaetanoG,
pubmed-author:BiffiMauroM,
pubmed-author:BorianiGiuseppeG,
pubmed-author:De SantoTizianaT,
pubmed-author:DragoFabrizioF,
pubmed-author:FontanaPierluigiP,
pubmed-author:MazziniElenaE,
pubmed-author:RubinoIdaI,
pubmed-author:SilvettiMassimo StefanoMS,
pubmed-author:SpitaliGirolamoG
|
pubmed:issnType |
Print
|
pubmed:volume |
30
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
1445-54
|
pubmed:meshHeading |
pubmed-meshheading:18070297-Adolescent,
pubmed-meshheading:18070297-Adult,
pubmed-meshheading:18070297-Aged,
pubmed-meshheading:18070297-Aged, 80 and over,
pubmed-meshheading:18070297-Algorithms,
pubmed-meshheading:18070297-Atrioventricular Node,
pubmed-meshheading:18070297-Cardiac Pacing, Artificial,
pubmed-meshheading:18070297-Chi-Square Distribution,
pubmed-meshheading:18070297-Child,
pubmed-meshheading:18070297-Child, Preschool,
pubmed-meshheading:18070297-Circadian Rhythm,
pubmed-meshheading:18070297-Electrodes, Implanted,
pubmed-meshheading:18070297-Female,
pubmed-meshheading:18070297-Heart Block,
pubmed-meshheading:18070297-Humans,
pubmed-meshheading:18070297-Infant,
pubmed-meshheading:18070297-Italy,
pubmed-meshheading:18070297-Linear Models,
pubmed-meshheading:18070297-Male,
pubmed-meshheading:18070297-Middle Aged,
pubmed-meshheading:18070297-Pacemaker, Artificial,
pubmed-meshheading:18070297-Sensory Thresholds,
pubmed-meshheading:18070297-Statistics, Nonparametric,
pubmed-meshheading:18070297-Treatment Outcome
|
pubmed:year |
2007
|
pubmed:articleTitle |
Atrial threshold variability: implications for automatic atrial stimulation algorithms.
|
pubmed:affiliation |
Istituto di Cardiologia, Università di Bologna, Bologna, Italy. mbiffi@aosp.bo.it
|
pubmed:publicationType |
Journal Article,
Multicenter Study
|