pubmed:abstractText |
In contrast with kidneys, data on hypothermic machine perfusion (HMP) of livers remain scarce. Optimal liver HMP is poorly defined. Superiority of liver HMP over simple cold storage (SCS), the current standard preservation, must be proven before HMP is applied clinically. In this study, morphology and adenosine triphosphate (ATP) contents of HMP livers at different flows and with versus without O(2) studied in a porcine ex vivo model were compared to SCS.
|