Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
12
pubmed:dateCreated
2007-12-6
pubmed:abstractText
The second-generation Histoplasma antigen immunoassay is semiquantitative, expressing results as a comparison to a negative control, which requires repeat testing of the prior specimen with the current specimen to accurately determine a change in antigen. Reporting results in this manner often is confusing to the ordering physician and laboratory. Development of a quantitative assay could improve accuracy, reduce interassay variability, and eliminate the need to test the prior sample with the current sample in the same assay. Calibrators with known concentrations of Histoplasma antigen were used to quantitate antigen in specimens from patients with histoplasmosis and from controls. Samples from cases of disseminated histoplasmosis or other mycoses and controls were tested to evaluate the performance characteristics of the quantitative assay. Paired specimens were evaluated to determine if quantitation eliminated the need to test the current and prior specimens in the same assay to assess a change in antigen. The sensitivity in samples from patients with AIDS and disseminated histoplasmosis was 100% in urine and 92.3% in serum. Cross-reactions occurred in 70% of other endemic mycoses, but not in aspergillosis. Specificity was 99% in controls with community-acquired pneumonia, medical conditions in which histoplasmosis was excluded, or healthy subjects. A change in antigen level categorized as an increase, no change, or decrease based on antigen units determined in the same assay agreed closely with the category of change in nanograms/milliliter determined from testing current and prior specimens in different assays. Sensitivity, specificity, and interassay precision are excellent in the new third-generation quantitative Histoplasma antigen immunoassay.
pubmed:grant
pubmed:commentsCorrections
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Dec
pubmed:issn
1556-679X
pubmed:author
pubmed:issnType
Electronic
pubmed:volume
14
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
1587-91
pubmed:dateRevised
2009-11-18
pubmed:meshHeading
pubmed:year
2007
pubmed:articleTitle
Detection of histoplasma antigen by a quantitative enzyme immunoassay.
pubmed:affiliation
MiraVista Diagnostics, 4444 Decatur Blvd., Indianapolis, IN 46241, USA. pconnolly@miravistalabs.com
pubmed:publicationType
Journal Article, Research Support, N.I.H., Extramural