pubmed:abstractText
Hypothermic machine perfusion (MP) of the liver has been reported to improve graft function reclaiming marginal livers, such as those from non-heart-beating donors. Livers from obese donors often have fatty infiltrates and are more susceptible to hypothermic conditions. No data exist about MP at temperatures >4 degrees C. This study evaluated liver function after organ preservation by comparing MP at 20 degrees C with conventional cold storage.