pubmed:abstractText |
We present the first described use of the Venture (St. Jude Medical Inc.) catheter to accomplish balloon crush stenting of a severely angulated bifurcation via the radial approach. We outline the lessons learned and pitfalls of performing percutaneous intervention to severely angulated bifurcations such as this one.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Aug
|
pubmed:issn |
1874-1754
|
pubmed:author | |
pubmed:issnType |
Electronic
|
pubmed:day |
9
|
pubmed:volume |
120
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
e6-8
|
pubmed:dateRevised |
2010-11-18
|
pubmed:meshHeading | |
pubmed:year |
2007
|
pubmed:articleTitle |
The Venture-balloon crush technique to treat a severely angulated bifurcation lesion via the radial approach--lessons learned.
|
pubmed:publicationType |
Letter,
Case Reports
|