Source:http://linkedlifedata.com/resource/pubmed/id/17483881
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
9
|
pubmed:dateCreated |
2007-8-7
|
pubmed:abstractText |
Osteolysis caused by wear particles from polyethylene in the artificial hip joints is a serious issue. We have used photo-induced radical graft polymerization to graft 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer onto the surface of cross-linked polyethylene (CLPE-g-MPC) in order to reduce friction and wear at the bearing surface of the joint. The physical and mechanical properties of CLPE and CLPE-g-MPC were not significantly different, expect that the friction coefficient of untreated CLPE cups was 0.0075, compared with 0.0009 for CLPE-g-MPC cup, an 88% reduction. After 3.0 x 10(6) cycles in the hip joint simulator test, we could not observe any wear of CLPE-g-MPC cups. We concluded that the advantage of photo-induced radical graft polymerization technique was that the grafted MPC polymer gave a high lubricity only on the surface and has no effect on the bulk properties of the CLPE substrate.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical |
http://linkedlifedata.com/resource/pubmed/chemical/Biocompatible Materials,
http://linkedlifedata.com/resource/pubmed/chemical/Methacrylates,
http://linkedlifedata.com/resource/pubmed/chemical/Phosphorylcholine,
http://linkedlifedata.com/resource/pubmed/chemical/Polyethylene,
http://linkedlifedata.com/resource/pubmed/chemical/poly(2-methacryloyloxyethyl-phosphor...
|
pubmed:status |
MEDLINE
|
pubmed:month |
Sep
|
pubmed:issn |
0957-4530
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
18
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
1809-15
|
pubmed:dateRevised |
2008-11-21
|
pubmed:meshHeading |
pubmed-meshheading:17483881-Biocompatible Materials,
pubmed-meshheading:17483881-Chemistry, Physical,
pubmed-meshheading:17483881-Hip Prosthesis,
pubmed-meshheading:17483881-Humans,
pubmed-meshheading:17483881-Materials Testing,
pubmed-meshheading:17483881-Methacrylates,
pubmed-meshheading:17483881-Microscopy, Electron, Transmission,
pubmed-meshheading:17483881-Phosphorylcholine,
pubmed-meshheading:17483881-Photochemistry,
pubmed-meshheading:17483881-Physicochemical Phenomena,
pubmed-meshheading:17483881-Polyethylene,
pubmed-meshheading:17483881-Prosthesis Failure,
pubmed-meshheading:17483881-Spectroscopy, Fourier Transform Infrared,
pubmed-meshheading:17483881-Spectrum Analysis,
pubmed-meshheading:17483881-X-Rays
|
pubmed:year |
2007
|
pubmed:articleTitle |
Effects of photo-induced graft polymerization of 2-methacryloyloxyethyl phosphorylcholine on physical properties of cross-linked polyethylene in artificial hip joints.
|
pubmed:affiliation |
Research and Development Corporate Division, Japan Medical Materials Corporation, Uemura Nissei Bldg 9F, 3-3-31 Miyahara, Osaka, Japan. kyomotom@jmmc.jp
|
pubmed:publicationType |
Journal Article,
In Vitro,
Research Support, Non-U.S. Gov't
|