pubmed:abstractText |
We examined the capabilities of the Vermont Knee Laxity Device (VKLD) in measuring varus (VR)-valgus (VL) and internal (INT)-external (EXT) rotational laxities by quantifying measurement consistency and absolute measurement error (N = 10). Based on the expected measurement error, we then examined side-to-side differences (N = 20). For all measures, the knee was flexed 20 degrees , the thigh securely fixed, and counterweights applied to the thigh and shank to create an initial zero shear and compressive load across the tibiofemoral joint. A 10-Nm torque was applied to the knee for VL and VR during non-weight-bearing, and a 5-Nm torque was applied for INT and EXT during non-weight-bearing and weight-bearing conditions. Position sensors measured angular displacements (deg). Except for INT during weight bearing, measurement consistency was good to excellent (range, 0.68-0.96), with absolute measurement errors generally less than 2 degrees for VR-VL and 3-4 degrees for INT-EXT. Although side-to-side differences were observed, they did not exceed absolute measurement errors. The VKLD yields reliable measures of VR-VL and INT-EXT laxities, with sufficient measurement precision to yield clinically relevant differences.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Aug
|
pubmed:issn |
0736-0266
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
25
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
981-8
|
pubmed:meshHeading |
pubmed-meshheading:17457828-Adult,
pubmed-meshheading:17457828-Biomechanics,
pubmed-meshheading:17457828-Female,
pubmed-meshheading:17457828-Humans,
pubmed-meshheading:17457828-Joint Instability,
pubmed-meshheading:17457828-Knee Joint,
pubmed-meshheading:17457828-Male,
pubmed-meshheading:17457828-Movement,
pubmed-meshheading:17457828-Reproducibility of Results,
pubmed-meshheading:17457828-Rotation
|
pubmed:year |
2007
|
pubmed:articleTitle |
Measurement of varus-valgus and internal-external rotational knee laxities in vivo--Part I: assessment of measurement reliability and bilateral asymmetry.
|
pubmed:affiliation |
Applied Neuromechanics Research Laboratory, Department of Exercise and Sport Science, University of North Carolina at Greensboro, 237B HHP Building, P.O. Box 26170, Greensboro, North Carolina 27402-6170, USA. sjshultz@uncg.edu
|
pubmed:publicationType |
Journal Article,
Validation Studies
|