Prosthetic replacement of the ascending aorta with nonelastic vascular grafts impairs the local Windkessel function. Whether this increases wall tension in the remaining aorta is still a not completely investigated hypothesis but is of clinical relevance with respect to postprocedural development of aneurysms and dissections, especially in the proximal descending aorta.