Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
1
pubmed:dateCreated
1992-2-10
pubmed:abstractText
To assess the feasibility, safety and usefulness of gradient-echo magnetic resonance imaging (MRI) combined with pharmacologic stress testing for the detection of coronary artery disease, 23 patients without previous myocardial infarction but with significant stenosis (greater than 70% diameter stenosis) of greater than or equal to 1 major coronary artery were selected for dipyridamole-MRI stress testing. Each patient underwent MRI at rest, and high-dose dipyridamole-MRI (0.75 mg/kg over 10 minutes) of corresponding basal and midventricular short-axis tomograms. Additionally, these patients performed symptom-limited exercise stress tests. All short-axis tomograms were evaluated on a standardized segmental basis by grading each segment as normal, hypokinetic, akinetic or dyskinetic. Dipyridamole-MRI was considered pathologic if segmental wall motion deteriorated by greater than or equal to 1 grade after dipyridamole. For comparison with coronary angiography, segmental wall motion gradings were related to the respective coronary artery territories in the short-axis plane. Pathologic dipyridamole-MRI was obtained in 18 of 23 (78%) patients. For 1- and 2-vessel diseases, sensitivity was 69 and 90%, respectively. Exercise stress tests were pathologic in 14 of 23 (66%) patients. For 1- and 2-vessel diseases, sensitivity of exercise stress test was 58% (7 of 12 patients) and 77% (7 of 9), respectively. Sensitivity/specificity of dipyridamole-MRI for the localization of the stenosed coronary artery was 78/100% for left anterior descending, 73/100% for left circumflex, and 88/87% for right coronary artery stenoses. It is concluded that dipyridamole-MRI is a feasible nonexercise-dependent test for detection and localization of functionally significant coronary artery disease.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
AIM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Jan
pubmed:issn
0002-9149
pubmed:author
pubmed:issnType
Print
pubmed:day
1
pubmed:volume
69
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
51-6
pubmed:dateRevised
2007-11-15
pubmed:meshHeading
pubmed:year
1992
pubmed:articleTitle
Feasibility of high-dose dipyridamole-magnetic resonance imaging for detection of coronary artery disease and comparison with coronary angiography.
pubmed:affiliation
Klinik III für Innere Medizin, Universität zu Köln, West Germany.
pubmed:publicationType
Journal Article, Comparative Study