Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
1
pubmed:dateCreated
2007-4-2
pubmed:abstractText
Four-dimensional EPR imaging involves a computationally intensive inversion of the sampled Radon transform. Conventionally, N-dimensional reconstructions have been carried out with N-1 stages of 2-D backprojection to exploit a dimension-dependent reduction in execution time. The huge data size of 4-D EPR imaging demands the use of a 3-stage reconstruction each consisting of 2-D backprojections. This gives three orders of magnitude reduction in computation relative to a single stage 4-D filtered backprojection. The multi-stage reconstruction, however, requires a uniform angular sampling that yields an inefficient distribution of gradient directions. We introduce a solution that involves acquisition of projections uniformly distributed in solid angle and reconstructs in three 2-D stages with the spatial uniform solid angle data set converted to uniform linear angular projections using 2-D interpolation. Images were taken from the two sampling schemes to compare the spatial resolution and the line width resolution. The degradation in the image quality due to the additional interpolation was small, and we achieved approximately 30% reduction in data acquisition time.
pubmed:grant
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/17197215-10341123, http://linkedlifedata.com/resource/pubmed/commentcorrection/17197215-10582707, http://linkedlifedata.com/resource/pubmed/commentcorrection/17197215-11782393, http://linkedlifedata.com/resource/pubmed/commentcorrection/17197215-12652539, http://linkedlifedata.com/resource/pubmed/commentcorrection/17197215-12768596, http://linkedlifedata.com/resource/pubmed/commentcorrection/17197215-15543780, http://linkedlifedata.com/resource/pubmed/commentcorrection/17197215-15862233, http://linkedlifedata.com/resource/pubmed/commentcorrection/17197215-16276490, http://linkedlifedata.com/resource/pubmed/commentcorrection/17197215-3035320, http://linkedlifedata.com/resource/pubmed/commentcorrection/17197215-8159757, http://linkedlifedata.com/resource/pubmed/commentcorrection/17197215-9703047, http://linkedlifedata.com/resource/pubmed/commentcorrection/17197215-9703055
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Mar
pubmed:issn
1090-7807
pubmed:author
pubmed:issnType
Print
pubmed:volume
185
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
152-8
pubmed:dateRevised
2011-9-26
pubmed:meshHeading
pubmed:year
2007
pubmed:articleTitle
Spatially uniform sampling in 4-D EPR spectral-spatial imaging.
pubmed:affiliation
Department of Radiation and Cellular Oncology, MC1105, University of Chicago Medical Center, University of Chicago, 5841 S. Maryland Ave. Chicago, IL 60637, USA.
pubmed:publicationType
Journal Article, Evaluation Studies, Research Support, N.I.H., Extramural