pubmed:abstractText
This paper presents the results of measurements made with the electronic personal neutron Saphydose-N during the four campaigns of the European contract EVIDOS (EValuation of Individual DOSimetry in mixed neutron and photon radiation fields). These measurements were performed at Institute for Radiological Protection and Nuclear Safety (IRSN) in France (C0), at the Krümmel Nuclear Power Plant in Germany (C1), at the VENUS Research Reactor and the Belgonucléaire fuel processing plant in Belgium (C2) and at the Ringhals Nuclear Power Plant in Sweden (C3). The results for Saphydose-N are compared with reference values for dose equivalent.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:issn
0144-8420
pubmed:author
pubmed:issnType
Print
pubmed:volume
125
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
271-4
pubmed:meshHeading
pubmed:year
2007
pubmed:articleTitle
Evaluation of dose equivalent by the electronic personal dosemeter for neutron 'Saphydose-N' at different workplaces of nuclear facilities.
pubmed:affiliation
Institute for Radiological Protection and Nuclear Safety, BP 17, 92262 Fontenay-aux-Roses, France. quang.chau@irsn.fr
pubmed:publicationType
Journal Article, Comparative Study, Evaluation Studies