Source:http://linkedlifedata.com/resource/pubmed/id/16959552
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
1-2
|
pubmed:dateCreated |
2007-1-29
|
pubmed:abstractText |
A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method with positive electrospray ionization (ESI) was developed for the quantification of ranolazine in human plasma. After liquid-liquid extraction of ranolazine and internal standard (ISTD) phenoprolamine from a 100 microl specimen of plasma, HPLC separation was achieved on a Nova-Pak C(18) column, using acetonitrile-water-formic acid-10% n-butylamine (70:30:0.5:0.08, v/v/v/v) as the mobile phase. The mass spectrometer was operated in multiple reaction monitoring (MRM) mode using the transition m/z 428.5-->m/z 279.1 for ranolazine and m/z 344.3-->m/z 165.1 for the internal standard, respectively. Linear calibration curves were obtained in the concentration range of 5-4000 ng/ml, with a lower limit of quantitation (LLOQ) of 5 ng/ml. The intra- and inter-day precision values were below 3.7% and accuracy was within +/-3.2% at all three quality control (QC) levels. This method was found suitable for the analysis of plasma samples collected during the phase I pharmacokinetic studies of ranolazine performed in 28 healthy volunteers after single oral doses from 200 mg to 800 mg.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Feb
|
pubmed:issn |
1570-0232
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
1
|
pubmed:volume |
846
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
346-50
|
pubmed:meshHeading |
pubmed-meshheading:16959552-Acetanilides,
pubmed-meshheading:16959552-Administration, Oral,
pubmed-meshheading:16959552-Calibration,
pubmed-meshheading:16959552-Chromatography, High Pressure Liquid,
pubmed-meshheading:16959552-Enzyme Inhibitors,
pubmed-meshheading:16959552-Humans,
pubmed-meshheading:16959552-Piperazines,
pubmed-meshheading:16959552-Reference Standards,
pubmed-meshheading:16959552-Reproducibility of Results,
pubmed-meshheading:16959552-Sensitivity and Specificity,
pubmed-meshheading:16959552-Spectrometry, Mass, Electrospray Ionization
|
pubmed:year |
2007
|
pubmed:articleTitle |
Sensitive quantification of ranolazine in human plasma by liquid chromatography--tandem mass spectrometry with positive electrospray ionization.
|
pubmed:affiliation |
Clinical Pharmacology Center, Fu Wai Hospital, CAMS and PUMC, 167 Beilishi Road, Beijing 100037, PR China.
|
pubmed:publicationType |
Journal Article,
Validation Studies
|