pubmed:abstractText
We report on a new electrodynamic ion funnel that operates at a pressure of 30 torr with no loss of ion transmission. The enhanced performance compared with previous ion funnel designs optimized for pressures of <5 torr was achieved by reducing the ion funnel capacitance and increasing the RF drive frequency (1.7 MHz) and amplitude (100-170 V peak-to-peak). No degradation of ion transmission was observed for pressures from 2 to 30 torr. The ability to operate at higher pressure enabled a new tandem ion funnel mass spectrometer interface design that can accommodate a greater gas load (e.g., from an ESI source). When combined with a multicapillary inlet, the interface provided more efficient introduction of ions, resulting in a significant enhancement in mass spectrometer sensitivity and detection limits.
pubmed:grant
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/16839773-10450147, http://linkedlifedata.com/resource/pubmed/commentcorrection/16839773-10631660, http://linkedlifedata.com/resource/pubmed/commentcorrection/16839773-10845370, http://linkedlifedata.com/resource/pubmed/commentcorrection/16839773-11338576, http://linkedlifedata.com/resource/pubmed/commentcorrection/16839773-11569805, http://linkedlifedata.com/resource/pubmed/commentcorrection/16839773-12216730, http://linkedlifedata.com/resource/pubmed/commentcorrection/16839773-14528493, http://linkedlifedata.com/resource/pubmed/commentcorrection/16839773-14588040, http://linkedlifedata.com/resource/pubmed/commentcorrection/16839773-15096064, http://linkedlifedata.com/resource/pubmed/commentcorrection/16839773-15253651, http://linkedlifedata.com/resource/pubmed/commentcorrection/16839773-15389859, http://linkedlifedata.com/resource/pubmed/commentcorrection/16839773-15734324, http://linkedlifedata.com/resource/pubmed/commentcorrection/16839773-15889926, http://linkedlifedata.com/resource/pubmed/commentcorrection/16839773-16194076, http://linkedlifedata.com/resource/pubmed/commentcorrection/16839773-2194402, http://linkedlifedata.com/resource/pubmed/commentcorrection/16839773-8779426, http://linkedlifedata.com/resource/pubmed/commentcorrection/16839773-9784749
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Sep
pubmed:issn
1044-0305
pubmed:author
pubmed:issnType
Print
pubmed:volume
17
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
1299-305
pubmed:dateRevised
2011-1-25
pubmed:meshHeading
pubmed:year
2006
pubmed:articleTitle
Improving mass spectrometer sensitivity using a high-pressure electrodynamic ion funnel interface.
pubmed:affiliation
Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, USA.
pubmed:publicationType
Journal Article, Research Support, U.S. Gov't, Non-P.H.S., Evaluation Studies