Source:http://linkedlifedata.com/resource/pubmed/id/16758455
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions |
umls-concept:C0005978,
umls-concept:C0010106,
umls-concept:C0022023,
umls-concept:C0028013,
umls-concept:C0030015,
umls-concept:C0030685,
umls-concept:C0068790,
umls-concept:C0087111,
umls-concept:C0205148,
umls-concept:C0332282,
umls-concept:C0391871,
umls-concept:C0486616,
umls-concept:C0680255,
umls-concept:C0683598,
umls-concept:C1280412,
umls-concept:C1280500,
umls-concept:C1283071,
umls-concept:C1963578
|
pubmed:issue |
1
|
pubmed:dateCreated |
2006-8-31
|
pubmed:abstractText |
Medical implants and devices are now used successfully in surgical procedures on a daily basis. Alloys of nickel and titanium, and in particular Nitinol are of special interest in the medical device industry, because of their shape memory and superelastic properties. The corrosion behavior of nitinol in the body is also of critical importance because of the known toxicological effects of nickel. The stability of a NiTi alloy in the physiological environment is dependant primarily on the properties of the mostly TiO(2) oxide layer that is present on the surface. For the present study, a range of nitinol wires have been prepared using different drawing processes and a range of surface preparation procedures. It is clear from the results obtained that the wire samples with very thick oxides also contain a high nickel content in the oxide layer. The untreated samples with the thicker oxides show the lowest pitting potential values and greater nickel release in both long and short-term experiments. It was also found that after long-term immersion tests breakdown potentials increased for samples that exhibited lower values initially. From these results it would appear that surface treatment is essential for the optimum bioperformance of nitinol.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical |
http://linkedlifedata.com/resource/pubmed/chemical/Alloys,
http://linkedlifedata.com/resource/pubmed/chemical/Biocompatible Materials,
http://linkedlifedata.com/resource/pubmed/chemical/Nickel,
http://linkedlifedata.com/resource/pubmed/chemical/Oxides,
http://linkedlifedata.com/resource/pubmed/chemical/nitinol
|
pubmed:status |
MEDLINE
|
pubmed:month |
Oct
|
pubmed:issn |
1549-3296
|
pubmed:author | |
pubmed:copyrightInfo |
(c) 2006 Wiley Periodicals, Inc
|
pubmed:issnType |
Print
|
pubmed:volume |
79
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
61-70
|
pubmed:meshHeading | |
pubmed:year |
2006
|
pubmed:articleTitle |
Influence of Nitinol wire surface treatment on oxide thickness and composition and its subsequent effect on corrosion resistance and nickel ion release.
|
pubmed:affiliation |
National Centre for Biomedical Engineering Science, National University of Ireland, Galway, Ireland. brenda.clarke@nuigalway.ie
|
pubmed:publicationType |
Journal Article
|