Source:http://linkedlifedata.com/resource/pubmed/id/16555771
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
3
|
pubmed:dateCreated |
2006-3-24
|
pubmed:abstractText |
An experimental system to take advantage of the imaging capabilities of a 5-ring polyvinylidene fluoride (PVDF)-based annular array is presented. The array has a 6-mm total aperture and a 12-mm geometric focus. The experimental system is designed to pulse a single element of the array and then digitize the received data of all array channels simultaneously. All transmit/receive pairs are digitized and then the data are post-processed with a synthetic-focusing technique to achieve an enhanced depth of field (DOF). The performance of the array is experimentally tested with a wire phantom consisting of 25-microm diameter wires diagonally spaced at 1-mm by 1-mm intervals. The phantom permitted the efficacy of the synthetic-focusing algorithm to be tested and was also used for two-way beam characterization. Experimental results are compared to a spatial impulse response method beam simulation. After synthetic focusing, the two-way echo amplitude was enhanced over the range of 8 to 19 mm and the 6-dB DOF spanned from 9 to 15 mm. For a wire at a fixed axial depth, the relative time delays between transmit/receive ring pairs agreed with theoretical predictions to within +/- 2 ns. To further test the system, B-mode images of an excised bovine eye were rendered.
|
pubmed:grant | |
pubmed:commentsCorrections |
http://linkedlifedata.com/resource/pubmed/commentcorrection/16555771-10385963,
http://linkedlifedata.com/resource/pubmed/commentcorrection/16555771-10687788,
http://linkedlifedata.com/resource/pubmed/commentcorrection/16555771-10870704,
http://linkedlifedata.com/resource/pubmed/commentcorrection/16555771-12824473,
http://linkedlifedata.com/resource/pubmed/commentcorrection/16555771-2734975,
http://linkedlifedata.com/resource/pubmed/commentcorrection/16555771-7195094,
http://linkedlifedata.com/resource/pubmed/commentcorrection/16555771-7199769,
http://linkedlifedata.com/resource/pubmed/commentcorrection/16555771-7754581,
http://linkedlifedata.com/resource/pubmed/commentcorrection/16555771-7777285
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:status |
PubMed-not-MEDLINE
|
pubmed:month |
Mar
|
pubmed:issn |
0885-3010
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
53
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
623-30
|
pubmed:dateRevised |
2010-8-9
|
pubmed:year |
2006
|
pubmed:articleTitle |
Operational verification of a 40-MHz annular array transducer.
|
pubmed:affiliation |
Riverside Research Institute, New York, NY, USA. ketterling@rrinyc.org
|
pubmed:publicationType |
Journal Article
|