Almost half of the X-ray beamlines at the Cornell High Energy Synchrotron Source (CHESS) are based on multilayer optics. ;Traditional' multilayers with an energy resolution of DeltaE/E approximately 2% are routinely used to deliver X-ray flux enhanced by a factor of 10(2) in comparison with standard Si(111) optics. Sagittal-focusing multilayers with fixed radius provide an additional factor of 10 gain in flux density. High-resolution multilayer optics with DeltaE/E approximately 0.2% are now routinely used by MacCHESS crystallographers. New wide-bandpass multilayers with DeltaE/E = 5% and 10% have been designed and tested for potential applications in macromolecular crystallography. Small d-spacing multilayers with d < or = 20 A have been successfully used to extend the energy range of multilayer optics. Analysis of the main characteristics of the Mo/B4C and W/B4C small d-spacing multilayer optics shows enhancement in their performance at higher energies. Chemical vapour deposited SiC, with a bulk thermal conductivity of a factor of two higher than that of silicon, has been successfully introduced as a substrate material for multilayer optics. Characteristics of different types of multilayer optics at CHESS beamlines and their applications in a variety of scattering, diffraction and imaging techniques are discussed.
|
pubmed:grant | |
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Mar
|
pubmed:issn |
0909-0495
|
pubmed:author |
pubmed-author:BilderbackDonald HDH,
pubmed-author:FontesErnestE,
pubmed-author:GrunerSol MSM,
pubmed-author:HaoQuanQ,
pubmed-author:KazimirovAlexanderA,
pubmed-author:MartynovVladimir VVV,
pubmed-author:PlatonovYuriyY,
pubmed-author:ShenQunQ,
pubmed-author:SmilgiesDetlef MDM,
pubmed-author:XiaoXianghuiX
|
pubmed:issnType |
Print
|
pubmed:volume |
13
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
204-10
|
pubmed:dateRevised |
2008-11-21
|
pubmed:meshHeading | |
pubmed:year |
2006
|
pubmed:articleTitle |
Multilayer X-ray optics at CHESS.
|
pubmed:affiliation |
Cornell High Energy Synchrotron Source (CHESS), Cornell University, Ithaca, NY 14853-8001, USA. ayk7@cornell.edu
|
pubmed:publicationType |
Journal Article,
Research Support, U.S. Gov't, Non-P.H.S.,
Research Support, N.I.H., Extramural
|