pubmed:abstractText |
A rapid (6.5 min) and simple one-step magnetic immunoassay (MIA) has been developed for analysis of human urinary albumin in near patient settings. Polyclonal rabbit anti-human albumin was used as a capture antibody and monoclonal mouse anti-human albumin as a detection antibody in a two-site immunometric assay requiring no additional washing procedures. The polyclonal anti-human albumin was conjugated to silica microparticles (solid phase) and the monoclonal antibody to dextran-coated nanoscaled superparamagnetic particles (tracer). Quantification of human albumin in undiluted urine was performed by adding 2 microL urine to a measuring vial containing solid-phase, superparamagnetic tracer and reaction buffer and then inverting the vial by hand for 20 s. The measuring vial was allowed to stand for 6 min prior to detection, in order for the solid-phase sediment to form at the bottom of the vial. Lastly, the measuring vial was placed into a magnetic permeability detector, which measured the enrichment of superparamagnetic tracer in the sediment due to complex formation with human albumin. Total analysis time was 6.5 min. A linear response was obtained for 0-400 mg/L albumin with a detection limit of 5 mg/L. The total coefficient of variation (CV) was 11% calculated from four consecutive runs on a urine sample containing 11.1 mg/L human albumin during 3 consecutive days. Human urinary albumin analysis was performed on 149 patient samples using the MIA technique and the obtained results showed good correlation with the hospital immunoturbidimetric reference method (y = 1.004x + 4.01, R2 = 0.978, N = 149) and a commercially available point of care albumin analysis provided by HemoCue Inc. (y = 0.98x + 5.8, R2 = 0.833, N = 90).
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Jun
|
pubmed:issn |
0956-5663
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
15
|
pubmed:volume |
21
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
2248-54
|
pubmed:dateRevised |
2009-7-14
|
pubmed:meshHeading |
pubmed-meshheading:16386414-Albumins,
pubmed-meshheading:16386414-Albuminuria,
pubmed-meshheading:16386414-Equipment Design,
pubmed-meshheading:16386414-Equipment Failure Analysis,
pubmed-meshheading:16386414-Feasibility Studies,
pubmed-meshheading:16386414-Humans,
pubmed-meshheading:16386414-Immunomagnetic Separation,
pubmed-meshheading:16386414-Magnetics,
pubmed-meshheading:16386414-Nanotechnology,
pubmed-meshheading:16386414-Urinalysis,
pubmed-meshheading:16386414-Urine
|
pubmed:year |
2006
|
pubmed:articleTitle |
A combination of magnetic permeability detection with nanometer-scaled superparamagnetic tracer and its application for one-step detection of human urinary albumin in undiluted urine.
|
pubmed:affiliation |
LifeAssays AB, Research Park Ideon, SE-223 70 Lund, Sweden.
|
pubmed:publicationType |
Journal Article,
Evaluation Studies
|